Single hollow fiber SLM extraction of polyamines followed by tosyl chloride derivatization and HPLC determination

被引:31
作者
Dziarkowsk, Katarzyna [2 ]
Jonsson, Jan Ake [1 ]
Wieczorek, Piotr P. [2 ]
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Opole Univ, Inst Chem, PL-45052 Opole, Poland
关键词
polyamines; supported liquid membrane; hollow fiber membrane; extraction technique;
D O I
10.1016/j.aca.2007.11.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Determination of polyamines in biological fluids possesses medical diagnostic relevance. Despite the vast panel of analytical methods developed for polyamines they are not applied in routine clinical usage, mainly due to the time and labor consuming sample preparation step and complicated derivatization. procedures. Thus, new simpler methods are needed. This paper describes a single hollow fiber SLM extraction method of polyarnines followed by simple pre-column derivatization with tosyl chloride and HPLC-UV analysis. The influence of different parameters such as the extraction time, organic phase composition, acceptor pH, donor pH, acceptor volume, donor volume and stirring speed on the transport parameters and enrichment was studied and discussed. The optimized method was applied to real matrices such as urine and plasma. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 193
页数:10
相关论文
共 31 条
[1]   Supported liquid membrane work-up of blood plasma samples coupled on-line to liquid chromatographic determination of basic antidepressant drugs [J].
Barri, T ;
Jönsson, JÅ .
CHROMATOGRAPHIA, 2004, 59 (3-4) :161-165
[2]   Determination of trace levels of dinitrophenolic compounds in environmental water samples using hollow fiber supported liquid membrane extraction and high performance liquid chromatography [J].
Berhanu, T ;
Liu, JF ;
Romero, R ;
Megersa, N ;
Jönsson, JÅ .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (01) :1-8
[3]   Why liquid membrane extraction is an attractive alternative in sample preparation [J].
Chimuka, L ;
Cukrowska, E ;
Jönsson, JA .
PURE AND APPLIED CHEMISTRY, 2004, 76 (04) :707-722
[4]   Peptides analysis in blood plasma using on-line system of supported liquid membrane and high-performance liquid chromatography [J].
Drapala, A ;
Jönsson, JÅ ;
Wieczorek, P .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :9-14
[5]  
DZIARKOWSKA K, IN PRESS J SEP SCI
[6]   ION-CHROMATOGRAPHIC DETERMINATION OF CARBOXYLIC-ACIDS IN AIR WITH ONLINE LIQUID MEMBRANE PRETREATMENT [J].
GRONBERG, L ;
SHEN, Y ;
JONSSON, JA .
JOURNAL OF CHROMATOGRAPHY A, 1993, 655 (02) :207-215
[7]   MEASUREMENT OF ALIPHATIC-AMINES IN AMBIENT AIR AND RAINWATER [J].
GRONBERG, L ;
LOVKVIST, P ;
JONSSON, JA .
CHEMOSPHERE, 1992, 24 (10) :1533-1540
[8]   Polyamines as clinical laboratory tools [J].
Gugliucci, A .
CLINICA CHIMICA ACTA, 2004, 344 (1-2) :23-35
[9]   Liquid membrane extraction in analytical sample preparation I.: Principles [J].
Jönsson, JÅ ;
Mathiasson, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :318-325
[10]   Liquid membrane extraction in analytical sample preparation II.: Applications [J].
Jönsson, JÅ ;
Mathiasson, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :325-334