Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations

被引:25
作者
Bierer, Julie Arenberg [1 ]
Deeks, John M. [2 ]
Billig, Alexander J. [2 ]
Carlyon, Robert P. [2 ]
机构
[1] Univ Washington, Dept Speech & Hearing Sci, Seattle, WA 98105 USA
[2] MRC, Cognit & Brain Sci Unit, Cambridge CB2 7EF, England
来源
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY | 2015年 / 16卷 / 02期
关键词
cochlear implants; gap detection; psychophysics; electrode configuration; ELECTRICAL-STIMULATION; LOUDNESS PERCEPTION; NEURAL RESPONSE; AUDITORY-NERVE; TEMPORAL PITCH; USERS; INTERFACE; TRIPOLAR; CHANNELS; LEVEL;
D O I
10.1007/s10162-015-0507-y
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Cochlear implant (CI) users usually exhibit marked across-electrode differences in detection thresholds with "focused" modes of stimulation, such as partial-tripolar (pTP) mode. This may reflect differences either in local neural survival or in the distance of the electrodes from the modiolus. To shed light on these two explanations, we compared stimulus-detection thresholds and gap-detection thresholds (GDTs) at comfortably loud levels for at least four electrodes in each of ten Advanced Bionics CI users, using 1031-pps pulse trains. The electrodes selected for each user had a wide range of stimulus-detection thresholds in pTP mode. We also measured across-electrode variations in both stimulus-detection and gap-detection tasks in monopolar (MP) mode. Both stimulus-detection and gap-detection thresholds correlated across modes. However, there was no significant correlation between stimulus-detection and gap-detection thresholds in either mode. Hence, gap-detection thresholds likely tap a source of across-electrode variation additional to, or different from, that revealed by stimulus-detection thresholds. Stimulus-detection thresholds were significantly lower for apical than for basal electrodes in both modes; this was only true for gap detection in pTP mode. Finally, although the across-electrode standard deviation in stimulus-detection thresholds was greater in pTP than in MP mode, the reliability of these differences-assessed by dividing the across-electrode standard deviation by the standard deviation across adaptive runs for each electrode-was similar for the two modes; this metric was also similar across modes for gap detection. Hence across-electrode differences can be revealed using clinically available MP stimulation, with a reliability comparable to that observed with focused stimulation.
引用
收藏
页码:273 / 284
页数:12
相关论文
共 20 条
[11]   Examining the Electro-Neural Interface of Cochlear Implant Users Using Psychophysics, CT Scans, and Speech Understanding [J].
Long, Christopher J. ;
Holden, Timothy A. ;
McClelland, Gary H. ;
Parkinson, Wendy S. ;
Shelton, Clough ;
Kelsall, David C. ;
Smith, Zachary M. .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2014, 15 (02) :293-304
[12]   Loudness perception with pulsatile electrical stimulation: The effect of interpulse intervals [J].
McKay, CM ;
McDermott, HJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (02) :1061-1074
[13]   Cochlear-implant high pulse rate and narrow electrode configuration impair transmission of temporal information to the auditory cortex [J].
Middlebrooks, John C. .
JOURNAL OF NEUROPHYSIOLOGY, 2008, 100 (01) :92-107
[14]   Effects of electrode-to-fiber distance on temporal neural response with electrical stimulation [J].
Mino, H ;
Rubinstein, JT ;
Miller, CA ;
Abbas, PJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (01) :13-20
[15]   Across-site variation in detection thresholds and maximum comfortable loudness levels for cochlear implants [J].
Pfingst, BE ;
Xu, L .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2004, 5 (01) :11-24
[16]   Effects of electrode configuration on cochlear implant modulation detection thresholds [J].
Pfingst, Bryan E. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (06) :3908-3915
[17]   TEMPORAL WINDOW SHAPE AS A FUNCTION OF FREQUENCY AND LEVEL [J].
PLACK, CJ ;
MOORE, BCJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (05) :2178-2187
[18]   Long-term sensorineural hearing loss induces functional changes in the rat auditory nerve [J].
Shepherd, RK ;
Roberts, LA ;
Paolini, AG .
EUROPEAN JOURNAL OF NEUROSCIENCE, 2004, 20 (11) :3131-3140
[19]   Electrical stimulation of the auditory nerve .1. Correlation of physiological responses with cochlear status [J].
Shepherd, RK ;
Javel, E .
HEARING RESEARCH, 1997, 108 (1-2) :112-144
[20]   Gap detection in single- and multiple-channel stimuli by LAURA cochlear implantees [J].
van Wieringen, A ;
Wouters, J .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 106 (04) :1925-1939