Experimental study of heat exchanger basing on absorption cycle for CHP system

被引:33
作者
Sun, Jian [1 ]
Fu, Lin [2 ]
Zhang, Shigang [2 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Beijing 102206, Peoples R China
[2] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
关键词
Absorption heat exchanger; AHE; Heat exchanger; Heat transfer; Heat pump; POWER-PLANT; RECOVERY; PIPES;
D O I
10.1016/j.applthermaleng.2016.03.138
中图分类号
O414.1 [热力学];
学科分类号
摘要
A heat exchange named "absorption heat exchanger" (AHE) is invented to instead of the conventional heat exchanger at the thermal substation. AHE could decrease the temperature of back water of primary pipe obviously, which is much lower than that of secondary pipe without changing original flowing rate. Working case of 120 degrees C/30 degrees C for primary pipe and 45 degrees C/60 degrees C for secondary pipe could come true without additional heat resource. AHE could increase the heating capacity of current heating pipes significantly, which is promising to meet the rapidly increasing requirement of heating in the future. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1280 / 1286
页数:7
相关论文
共 27 条
[1]   Plate heat exchangers: Recent advances [J].
Abu-Khader, Mazen M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (04) :1883-1891
[2]   RECOVERY AND UTILIZATION OF WASTE HEAT [J].
ALRABGHI, OM ;
BEIRUTTY, M ;
AKYURT, M ;
NAJJAR, Y ;
ALP, T .
HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (05) :463-470
[3]  
[Anonymous], 2011, 2011 ANN REP CHIN BU
[4]  
[Anonymous], HEAT TRANSFER
[5]   Numerical modelling and experimental measurements for a low-temperature district heating substation for instantaneous preparation of DHW with respect to service pipes [J].
Brand, Marek ;
Thorsen, Jan Eric ;
Svendsen, Svend .
ENERGY, 2012, 41 (01) :392-400
[6]   Modelling of waste heat recovery for combined heat and power applications [J].
Descombes, Georges ;
Boudigues, Serge .
APPLIED THERMAL ENGINEERING, 2009, 29 (13) :2610-2616
[7]   Heat transfer-A review of 2005 literature [J].
Goldstein, R. J. ;
Ibele, W. E. ;
Patankar, S. V. ;
Simon, T. W. ;
Kuehn, T. H. ;
Strykowski, P. J. ;
Tamma, K. K. ;
Heberlein, J. V. R. ;
Davidson, J. H. ;
Bischof, J. ;
Kulacki, F. A. ;
Kortshagen, U. ;
Garrick, S. ;
Srinivasan, V. ;
Ghosh, K. ;
Mittal, R. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (21-22) :4397-4447
[8]   Improved district heating substation efficiency with a new control strategy [J].
Gustafsson, Jonas ;
Delsing, Jerker ;
van Deventer, Jan .
APPLIED ENERGY, 2010, 87 (06) :1996-2004
[9]   Quasi-dynamic energy-saving judgment of electric-driven seawater source heat pump district heating system over boiler house district heating system [J].
Haiwen, Shu ;
Duanmu, Lin ;
Xiangli, Li ;
Yingxin, Zhu .
ENERGY AND BUILDINGS, 2010, 42 (12) :2424-2430
[10]   Application of customized absorption heat pumps for utilization of low-grade heat sources [J].
Keil, Christian ;
Plura, Stefan ;
Radspieler, Michael ;
Schweigler, Christian .
APPLIED THERMAL ENGINEERING, 2008, 28 (16) :2070-2076