Crosstalk in an FDM Laboratory Setup and the Athena X-IFU End-to-End Simulator

被引:5
作者
den Hartog, R. [1 ]
Kirsch, C. [2 ,3 ]
de Vries, C. [1 ]
Akamatsu, H. [1 ]
Dauser, T. [2 ,3 ]
Peille, P. [4 ]
Cucchetti, E. [5 ]
Jackson, B. [6 ]
Bandler, S. [7 ]
Smith, S. [7 ]
Wilms, J. [2 ,3 ]
机构
[1] SRON Netherlands Inst Space Res, Utrecht, Netherlands
[2] Remeis Observ, Bamberg, Germany
[3] ECAP, Erlangen, Germany
[4] CNES, Toulouse, France
[5] CNRS, IRAP, Toulouse, France
[6] SRON Netherlands Inst Space Res, Groningen, Netherlands
[7] NASA, Goddard Space Flight Ctr, Greenbelt, MD USA
关键词
Athena; X-IFU; TES; FDM; Crosstalk;
D O I
10.1007/s10909-018-1901-8
中图分类号
O59 [应用物理学];
学科分类号
摘要
The impact of various crosstalk mechanisms on the performance of the Athena X-IFU instrument has been assessed with detailed end-to-end simulations. For the crosstalk in the electrical circuit, a detailed model has been developed. In this contribution, we test this model against measurements made with an FDM laboratory setup and discuss the assumption of deterministic crosstalk in the context of the weak link effect in the detectors. We conclude that crosstalk levels predicted by the model are conservative with respect to the observed levels.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 13 条
[1]   Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena [J].
Akamatsu, Hiroki ;
Gottardi, Luciano ;
van der Kuur, Jan ;
de Vries, Cor P. ;
Ravensberg, Kevin ;
Adams, Joseph S. ;
Bandler, Simon R. ;
Bruijn, Marcel P. ;
Chervenak, James A. ;
Kilbourne, Caroline A. ;
Kiviranta, Mikko ;
van der Linden, A. J. ;
Jackson, Brian D. ;
Smith, Stephen J. .
SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
[2]   The Athena X-ray Integral Field Unit (X-IFU) [J].
Barret, Didier ;
Thien Lam Trong ;
den Herde, Jan-Willem ;
Piro, Luigi ;
Barcons, Xavier ;
Huovelin, Juhani ;
Kelley, Richard ;
Miguel Mas-Hesse, J. ;
Mitsuda, Kazuhisa ;
Paltani, Stephane ;
Rauw, Gregor ;
Rozanska, Agata ;
Wilms, Joern ;
Barbera, Marco ;
Bozzo, Enrico ;
Teresa Ceballos, Maria ;
Charles, Ivan ;
Decourchelle, Anne ;
den Hartog, Roland ;
Duval, Jean-Marc ;
Fiore, Fabrizio ;
Gatti, Flavio ;
Goldwurm, Andrea ;
Jackson, Brian ;
Jonker, Peter ;
Kilbourne, Caroline ;
Macculi, Claudio ;
Mendez, Mariano ;
Molendi, Silvano ;
Orleanski, Piotr ;
Pajot, Francois ;
Pointecouteau, Etienne ;
Porter, Frederick ;
Pratt, Gabriel W. ;
Prele, Damien ;
Ravera, Laurent ;
Renotte, Etienne ;
Schaye, Joop ;
Shinozaki, Keisuke ;
Valenziano, Luca ;
Vink, Jacco ;
Webb, Natalie ;
Yamasaki, Noriko ;
Delcelier-Douchin, Francoise ;
Le Du, Michel ;
Mesnager, Jean-Michel ;
Pradines, Alice ;
Branduardi-Raymont, Graziella ;
Dadina, Mauro ;
Finoguenov, Alexis .
SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
[3]   Tailoring the High-Q LC Filter Arrays for Readout of Kilo-Pixel TES Arrays in the SPICA-SAFARI Instrument [J].
Bruijn, M. P. ;
Gottardi, L. ;
den Hartog, R. H. ;
van der Kuur, J. ;
van der Linden, A. J. ;
Jackson, B. D. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (3-4) :421-425
[4]   The impact of crosstalk in the X-IFU instrument on Athena science cases [J].
den Hartog, R. ;
Peille, P. ;
Dauser, T. ;
Jackson, B. ;
Bandler, S. ;
Barrett, D. ;
Brand, T. ;
den Herder, J. -W. ;
Kiviranta, M. ;
van der Kuur, J. ;
Smiths, S. ;
Wilms, J. .
SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
[5]   Frequency multiplexed superconducting quantum interference device readout of large bolometer arrays for cosmic microwave background measurements [J].
Dobbs, M. A. ;
Lueker, M. ;
Aird, K. A. ;
Bender, A. N. ;
Benson, B. A. ;
Bleem, L. E. ;
Carlstrom, J. E. ;
Chang, C. L. ;
Cho, H. -M. ;
Clarke, J. ;
Crawford, T. M. ;
Crites, A. T. ;
Flanigan, D. I. ;
de Haan, T. ;
George, E. M. ;
Halverson, N. W. ;
Holzapfel, W. L. ;
Hrubes, J. D. ;
Johnson, B. R. ;
Joseph, J. ;
Keisler, R. ;
Kennedy, J. ;
Kermish, Z. ;
Lanting, T. M. ;
Lee, A. T. ;
Leitch, E. M. ;
Luong-Van, D. ;
McMahon, J. J. ;
Mehl, J. ;
Meyer, S. S. ;
Montroy, T. E. ;
Padin, S. ;
Plagge, T. ;
Pryke, C. ;
Richards, P. L. ;
Ruh, J. E. ;
Schaffer, K. K. ;
Schwan, D. ;
Shirokoff, E. ;
Spieler, H. G. ;
Staniszewski, Z. ;
Stark, A. A. ;
Vanderlinde, K. ;
Vieira, J. D. ;
Vu, C. ;
Westbrook, B. ;
Williamson, R. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07)
[6]  
Gottardi L., 2017, COMMUNICATION
[7]   Readout of a 176 pixel FDM system for SAFARI TES arrays [J].
Hijmering, R. A. ;
den Hartog, R. ;
Ridder, M. ;
van der Linden, A. J. ;
van der Kuur, J. ;
Gao, J. R. ;
Jackson, B. .
MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VIII, 2016, 9914
[8]   Heat Sinking, Crosstalk, and Temperature Uniformity for Large Close-Packed Microcalorimeter Arrays [J].
Iyomoto, N. ;
Bandler, S. R. ;
Brekosky, R. P. ;
Brown, A. -D. ;
Chervenak, J. A. ;
Eckart, M. E. ;
Finkbeiner, F. M. ;
Kelley, R. L. ;
Kilbourne, C. A. ;
Porter, F. S. ;
Sadleir, J. E. ;
Smith, S. J. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) :557-560
[9]   The focal plane assembly for the Athena X-ray Integral Field Unit instrument [J].
Jackson, B. D. ;
van Weers, H. ;
van der Kuur, J. ;
den Hartog, R. ;
Akamatsu, H. ;
Argan, A. ;
Bandler, S. R. ;
Barbera, M. ;
Barret, D. ;
Bruijn, M. P. ;
Chervenak, J. A. ;
Dercksen, J. ;
Gatti, F. ;
Gottardi, L. ;
Haas, D. ;
den Herder, J. -W. ;
Kilbourne, C. A. ;
Kiviranta, M. ;
Lam-Trong, T. ;
van Leeuwen, B. -J. ;
Macculi, C. ;
Piro, L. ;
Smith, S. J. .
SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
[10]  
Peille P., 2017, J LOW TEMP PHYS