Investigation of breakdown voltage and electrical breakdown time delay in air-filled tube in presence of combined gas and vacuum breakdown mechanism

被引:15
|
作者
Pejovic, Momcilo M. [1 ]
Zivanovic, Emilija N. [1 ]
Pejovic, Milic M. [1 ]
Nesic, Nikola T. [1 ]
Kovacevic, Dragan [2 ]
机构
[1] Univ Nis, Fac Elect Engn, Nish 18000, Serbia
[2] Inst Elect Engn Nikola Tesla, Belgrade 11000, Serbia
关键词
Afterglow period; Breakdown voltage; Time delay of electrical breakdown; Vacuum electrical breakdown; SIMPLE EXPRESSIONS; UV-RADIATION; LOW-PRESSURE; PROBABILITY; NITROGEN; APPLICABILITY; GAMMA; NEON;
D O I
10.1016/j.vacuum.2012.04.034
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the experimental data of breakdown voltage and electrical breakdown time delay for air-filled tube at p = 0.7 mbar pressure. The breakdown voltage was measured for product p.d (d is inter-electrode gap) from 0.005 to 0.2 mbar cm, i.e. when breakdown was a consequence of gas and vacuum mechanisms combined. It was shown that the static breakdown voltage, which was determined from experimental data of the dynamic breakdown voltage, retains approximately constant value. The shape of the memory curve, which displays the mean value of electrical breakdown time delay (t) over bar (d) vs. relaxation time tau, is very similar to that previously obtained in the case of breakdown induced by Townsend's mechanism alone. UV and gamma radiation lead to the decrease of (t) over bar (d) values for values tau > 30 ms and this decrease is larger in the presence of UV radiation. UV and gamma radiation shorten the relaxation time needed for memory curve to reach saturation. On the basis of exponential and Gaussian distributions of experimental data, the contribution of the statistical time delay and the formative time to total electrical breakdown time delay for different values of relaxation time is considered. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1860 / 1866
页数:7
相关论文
共 50 条
  • [1] Experimental investigation of breakdown voltage and electrical breakdown time delay of commercial gas discharge tubes
    Pejović, Milić Momčilo
    Pejović, Momčilo Milić
    Stanković, Koviljka
    Japanese Journal of Applied Physics, 2011, 50 (8 PART 1):
  • [2] Experimental Investigation of Breakdown Voltage and Electrical Breakdown Time Delay of Commercial Gas Discharge Tubes
    Pejovic, Milic Momcilo
    Pejovic, Momcilo Milic
    Stankovic, Koviljka
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (08)
  • [3] Separation of vacuum and gas breakdown processes in argon and their influence on electrical breakdown time delay
    Pejović, Milić
    Pejović, Momčilo
    Belić, Čedomir
    Stanković, Koviljka
    Vacuum, 2020, 173
  • [4] Separation of vacuum and gas breakdown processes in argon and their influence on electrical breakdown time delay
    Pejovic, Milic
    Pejovic, Momcilo
    Belic, Cedomir
    Starikovic, Koviljka
    VACUUM, 2020, 173
  • [5] Microwave breakdown in air-filled resonators
    Olsson, T
    Andersson, D
    Jordan, U
    Lisak, M
    Semenov, V
    Åhlander, M
    1999 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-4, 1999, : 915 - 918
  • [6] Investigation of the statistical nature and structure of the electrical breakdown time delay in gas diodes filled with neon
    Maluckov, Cedomir A.
    Karamarkovic, Jugoslav P.
    Radovic, Miodrag K.
    PHYSICS OF IONIZED GASES, 2006, 876 : 317 - +
  • [7] Vacuum electrical breakdown mechanism
    Krstic, S
    Osmokrovic, P
    Kartalovic, N
    Ostojic, D
    18TH SPIG - 18TH SUMMER SCHOOL AND INTERNATIONAL SYMPOSIUM ON THE PHYSICS OF IONIZED GASES: CONTRIBUTED PAPERS & ABSTRACTS OF INVITED LECTURES AND PROGRESS REPORTS, 1996, : 424 - 427
  • [8] MEMORY EFFECT IN AIR IN THE PRESENCE OF VACUUM BREAKDOWN MECHANISM
    Zivanovic, E. N.
    Pejovic, M. M.
    24TH SUMMER SCHOOL AND INTERNATIONAL SYMPOSIUM ON THE PHYSICS OF IONIZED GASES, CONTRIBUTED PAPERS, 2008, (84): : 293 - 296
  • [9] Investigations of breakdown voltage and time delay of gas-filled surge arresters
    Pejovic, Milic M.
    Pejovic, Momcilo M.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (20) : 4417 - 4422
  • [10] ELECTRICAL BREAKDOWN TIME DELAY IN COMMERCIAL GAS-FILLED SURGE ARRESTERS
    Pejovic, Milic
    Dekic, Sasa
    Jovanovic, Bojan
    Fetahovic, Irfan
    Osmokrovic, Predrag
    2015 IEEE PULSED POWER CONFERENCE (PPC), 2015,