Towards optimal model-based partial volume effect correction in oncological PET imaging

被引:0
|
作者
Schoenahl, F [1 ]
Zaidi, H [1 ]
机构
[1] Geneva Univ Hosp, Div Nucl Med, CH-1211 Geneva, Switzerland
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Quantification of tumor uptake in nuclear medicine requires the assessment of the tumor size. We propose a method based on simple ellipsoidal models which only require the reconstructed image data and scanner physical parameters. The method uses simple image and system models but is theoretically not sensitive to the reconstructed image sampling, provided that the local resolution parameters of the scanner are known. Interpolation is thus avoided and the degradation model is computed analytically. The proposed method uses the property that the blurring effect of the scanner spreads the activity around the lesion location and in the neighbor-voxels-even for sub-voxel sized lesions - and attempts to use this limited information to accurately restore lesion parameters. We propose solutions to avoid bias and reduce computation time. The uptake of simple simulated tumor objects could be restored and the influence of lesion's shape and neighborhood was investigated on real patient data for which convergence of the algorithm was demonstrated. This approach is a contribution towards in-depth investigation of reconstruction/post-reconstruction-based models for tumor activity restoration based on more complex image and system models.
引用
收藏
页码:3177 / 3181
页数:5
相关论文
共 50 条
  • [31] Partial Volume Correction Methods Based on Measured Lesion-to-Background Ratio in PET-CT Oncological Studies
    Gallivanone, F.
    Stefano, A.
    Gilardi, M. C.
    Messa, C.
    Canevari, C.
    Castiglioni, I.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 360 - 363
  • [32] Partial Volume Correction Strategies in PET
    Rousset, Olivier
    Rahmim, Arman
    Alavi, Abass
    Zaidi, Habib
    PET CLINICS, 2007, 2 (02) : 235 - 249
  • [33] Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view
    Krempser, Alexandre R.
    Ichinose, Roberto M.
    Miranda de Sa, Antonio M. F. L.
    Velasques de Oliveira, Silvia M.
    Carneiro, Michel P.
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (10) : 924 - 930
  • [34] Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view
    Alexandre R. Krempser
    Roberto M. Ichinose
    Antonio M. F. L. Miranda de Sá
    Silvia M. Velasques de Oliveira
    Michel P. Carneiro
    Annals of Nuclear Medicine, 2013, 27 : 924 - 930
  • [35] Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging
    Chang, Guoping
    Chang, Tingting
    Pan, Tinsu
    Clark, John W., Jr.
    Mawlawi, Osama R.
    MEDICAL PHYSICS, 2010, 37 (12) : 6221 - 6232
  • [36] Iterative-based Partial Volume Effects correction with wavelet-based regularization for quantitative PET imaging
    Reilhac, Anthonin
    Lehnert, Wencke
    Lin, Jianyu
    Meikle, Steven R.
    Gregoire, Marie-Claude
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3788 - 3791
  • [37] Impact of partial-volume correction in oncological PET studies: a systematic review and meta-analysis
    Cysouw, Matthijs C. F.
    Kramer, Gerbrand M.
    Schoonmade, Linda J.
    Boellaard, Ronald
    de Vet, Henrica C. W.
    Hoekstra, Otto S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (12) : 2105 - 2116
  • [38] Impact of partial-volume correction in oncological PET studies: a systematic review and meta-analysis
    Matthijs C. F. Cysouw
    Gerbrand M. Kramer
    Linda J. Schoonmade
    Ronald Boellaard
    Henrica C. W. de Vet
    Otto S. Hoekstra
    European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 2105 - 2116
  • [39] Partial Volume Correction for Subregional Analysis of Striatal Uptake in Dopaminergic PET Imaging
    Lue, K. H.
    Lin, H. H.
    Kao, C. H.
    Hsieh, H. J.
    Liu, S. H.
    Chuang, K. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S346 - S346
  • [40] Objective evaluation of voxelwise partial volume correction methods in brain PET imaging
    Bilgel, Murat
    Zhu, Yansong
    Rousset, Olivier
    Wong, Dean
    Resnick, Susan
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61