The Corrosion Process of an API 5L X80 Welded Joint in a System with Different pH and H2S Concentration

被引:0
作者
Carvalho, M. B. L. [1 ]
Bott, I. S. [1 ]
Forero, A. B. [2 ]
Ponciano, J. A. C. [3 ]
机构
[1] Pontificia Univ Catolica Rio de Janeiro, Dept Engn Quim & Mat, Rua Marques de Sao Vicente 225, BR-22453900 Rio De Janeiro, RJ, Brazil
[2] Compania Massy Energy Colombia, Cra 45A N 93-64, Bogota, Colombia
[3] Univ Fed Rio de Janeiro, Ctr Tecnol, Dept Engn Met & Mat, Lab Corrosao LabCorr, Ave Horacio Macedo 2030,Bloco F,Cidade Univ, BR-21941598 Rio De Janeiro, RJ, Brazil
来源
MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS | 2022年 / 25卷
关键词
Corrosion; H2S; API 5L X80; Welded joint; Electrochemical tests; Weight loss tests; HYDROGEN-INDUCED CRACKING; PIPELINE STEELS; HEAT-TREATMENT; SULFIDE; BEHAVIOR; MICROSTRUCTURE; SUSCEPTIBILITY; RESISTANCE; STRENGTH; IRON;
D O I
10.1590/1980-5373-MR-2021-0443
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The corrosion evaluation of steels in the oil and gas industry environments is a crucial issue because corrosion can cause economic and human losses. It is well known that H2S can be originated from different processes in the oil and gas industry, accelerating the corrosion process. The objective of this work was to evaluate the H2S corrosion resistance of an API 5L X80 steel and its welded joint obtained by submerged arc welding process (SAW). All tests were performed in an aerated 5% wt NaCl and thiosulphate aqueous solution. The H2S concentration, pH, weight loss, electrochemical tests, and microstructure were considered. The results obtained showed an increase of the corrosion rate values, with decreasing pH and increasing concentration of H2S generated by the thiosulphate. For the lowest H2S concentrations, the corrosion process was inhibited, due to the formation of a partially protective film on the samples' surfaces. The heat affected zone (HAZ) showed severe localized corrosion attack which was attributed to the microstructural characteristics of this region.
引用
收藏
页数:11
相关论文
共 29 条
  • [1] Effect of heat treatment on the stress corrosion resistance of a microalloyed pipeline steel
    Albarran, JL
    Martinez, L
    Lopez, HF
    [J]. CORROSION SCIENCE, 1999, 41 (06) : 1037 - 1049
  • [2] [Anonymous], 2000, PROC 3TH INT PIPELIN
  • [3] Electrochemical behavior of API X70 steel in hydrogen sulfide-containing solutions
    Arzola, S.
    Mendoza-Flores, J.
    Duran-Romero, R.
    Genesca, J.
    [J]. CORROSION, 2006, 62 (05) : 433 - 443
  • [4] ASTM: American Society for Testing and Materials, 2003, G5997 ASTM
  • [5] ASTM: American Society for Testing and Materials, 2012, G103 ASTM
  • [6] ASTM: American Society for Testing and Materials, 2011, D268811 ASTM
  • [7] Ballesteros AF, 2015, MATER RES-IBERO-AM J, V18, P417
  • [8] High-strength steel development for pipelines: A Brazilian perspective
    Bott, ID
    De Souza, LFG
    Teixeira, JCG
    Rios, PR
    [J]. METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2005, 36A (02): : 443 - 454
  • [9] Bulger J, 2000, INT PIP C 2000 OCT 1
  • [10] The influence of chemical composition and microstructure of API linepipe steels on hydrogen induced cracking and sulfide stress corrosion cracking
    Carneiro, RA
    Ratnapuli, RC
    Lins, VD
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2003, 357 (1-2): : 104 - 110