Improving Youden plots by including analytical performance specifications

被引:4
作者
Coucke, Wim [1 ]
Soumali, Mohamed Rida [1 ]
Badrick, Tony [2 ]
机构
[1] Sciensano, Qual Labs, J Wytsmanstr 14, B-1040 Brussels, Belgium
[2] Royal Coll Pathologists Australasia Qual Assuranc, Suite 201,Level 2,8 Herbert St, Sydney, NSW 2065, Australia
关键词
Youden plots; External Quality Assessment; Analytical Performance Specifications;
D O I
10.1016/j.cca.2022.04.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Historically, Youden plots are made of a scatter plot of the results of two EQA samples with an elliptical confidence area around them. Because Youden plots compare individual laboratory results with respect to other laboratories, they intrinsically evaluate with state of the art. In the field of medical laboratory science, analytical performance specifications have been proposed and various EQA providers show these limits on Youden plots by horizontal and vertical lines near the limits of total error. This study shows the weaknesses of these limits of total error and proposes a new approach for drawing acceptance areas on Youden plots. The classical Youden plot is extended with two acceptance areas: A first acceptance area evaluates the reported results with respect to maximum allowed variability, a second acceptance area evaluates the results with respect to maximum allowed variability and bias. The ellipses are calculated using quantiles of the Chi-square and noncentral Chi-square distribution. Results show that the new approach allows evaluating results from individual laboratories and from measurement procedures by comparing the position and overlap of the confidence area and the acceptance areas. It is demonstrated that his approach controls the type I error better than the rectangular limits.
引用
收藏
页码:212 / 216
页数:5
相关论文
共 9 条
[1]   A framework for evaluating the frequency of external quality assessment challenges [J].
Coucke, Wim ;
Soumali, Mohamed Rida ;
Graham, Peter ;
Shepherd, Samantha ;
Badrick, Tony .
CLINICA CHIMICA ACTA, 2022, 527 :71-78
[2]   Demystifying EQA statistics and reports [J].
Coucke, Wim ;
Soumali, Mohamed Rida .
BIOCHEMIA MEDICA, 2017, 27 (01) :37-48
[3]  
EFLM Biological Variation, EFLM BIOL VAR DAT
[4]  
International Organization for Standardization, 2015, 135282015 ISO
[5]  
Murdoch Duncan, 2023, CRAN, DOI 10.32614/CRAN.package.ellipse
[6]   A fast algorithm for the minimum covariance determinant estimator [J].
Rousseeuw, PJ ;
Van Driessen, K .
TECHNOMETRICS, 1999, 41 (03) :212-223
[7]   A study on the utilization of the Youden plot to evaluate proficiency test results [J].
Shirono, Katsuhiro ;
Iwase, Kosei ;
Okazaki, Hiroshi ;
Yamazawa, Masaru ;
Shikakume, Kazuhiro ;
Fukumoto, Natsuo ;
Murakami, Masashi ;
Yanagisawa, Masaaki ;
Tsugoshi, Takahisa .
ACCREDITATION AND QUALITY ASSURANCE, 2013, 18 (03) :161-174
[8]  
Wu GB, 1996, FLOW MEAS INSTRUM, V7, P19, DOI 10.1016/0955-5986(96)00007-6
[9]   Comparison of traditional, trimmed traditional and robust Youden charts [J].
Zhou, Qi ;
Hu, Jihong ;
Li, Xiaopeng ;
Li, Shaonan ;
Gao, Zhenxiang ;
Xie, Wei ;
Xu, Jianping .
CLINICA CHIMICA ACTA, 2015, 446 :213-217