Gastrografin can be detected in ex vivo biological specimens by dual-energy CT scanning

被引:4
作者
Clark, David A. [1 ,2 ,3 ,4 ]
Yeoh, Edward [5 ]
Edmundson, Aleksandra [2 ,3 ]
Pratap, Jit [5 ]
Snow, Tom [2 ,4 ]
Solomon, Michael [1 ]
Coucher, John [5 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sydney, NSW, Australia
[2] Royal Brisbane & Womens Hosp, Dept Surg, Brisbane, Qld, Australia
[3] Univ Queensland, Fac Med, Brisbane, Qld, Australia
[4] St Vincents Private Hosp Northside, 627 Rode Rd, Brisbane, Qld 4032, Australia
[5] Princess Alexandra Hosp, Dept Med Imaging, Brisbane, Qld, Australia
关键词
Gastrografin; dual-energy CT; iodine measurement; biomarker; iodine quantification;
D O I
10.1111/1754-9485.13071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Dual-energy CT is able to distinguish between materials based on differences in X-ray absorption at different X-ray beam energies. The strong k-edge photoelectric effect of materials with a high atomic number makes this modality ideal for identifying iodine-containing compounds. We aim to evaluate dual-energy CT for the detection of Gastrografin (GG) (diatrizoate, Bayer PLC, Reading, UK) enteric contrast medium and validate the conditions for the measurement in ex vivo samples. Methods Dual-energy CT acquisitions were performed to detect Gastrografin in serial dilutions of water, saline and body fluids. We also evaluated the stability of Gastrografin solutions over time at room temperature. Stool specimens were examined to validate the proposed study protocol for clinical applications. Results Concentrations as low as 0.2% of Gastrografin were reproducibly detected in vitro and ex vivo samples by DECT, with linear readings ranging from 0.2% to 25% Gastrografin. Gastrografin was shown to be stable in ex vivo biological samples, and there was no difference in detection over time. Gastrografin was detected in stool specimens when administered orally. The detection curves followed the expected saturation effect at high concentrations of iodine. Conclusions Dual-energy CT offers a convenient, quick, reliable and reproducible method for detecting and quantifying the presence of Gastrografin in ex vivo clinical specimens. Biological solutions containing Gastrografin are stable over time. A minimum dilution level of 25% is suggested to avoid beam saturation and inaccurate results.
引用
收藏
页码:634 / 640
页数:7
相关论文
共 9 条
[1]   Dual-energy computed tomography (DECT) in emergency radiology: Basic principles, techniques, and limitations [J].
Aran S. ;
Shaqdan K.W. ;
Abujudeh H.H. .
Emergency Radiology, 2014, 21 (4) :391-405
[2]   Drain fluid amylase as a sensitive biomarker for the early detection of anastomotic leakage in ileal pouch surgery [J].
Clark, D. A. ;
Cuda, T. ;
Riddell, A. ;
Radford-Smith, G. ;
Solomon, M. .
COLORECTAL DISEASE, 2019, 21 (04) :460-464
[3]   Technical limitations of dual-energy CT in neuroradiology: 30-month institutional experience and review of literature [J].
Dinkel, Julien ;
Khalilzadeh, Omid ;
Phan, Catherine M. ;
Goenka, Ajit H. ;
Yoo, Albert J. ;
Hirsch, Joshua A. ;
Gupta, Rajiv .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (08) :596-602
[4]   Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440
[5]   Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study [J].
Jacobsen, Megan C. ;
Schellingerhout, Dawid ;
Wood, Cayla A. ;
Tamm, Eric P. ;
Godoy, Myrna C. ;
Sun, Jia ;
Cody, Dianna D. .
RADIOLOGY, 2018, 287 (01) :224-234
[6]  
Johnson TRC, 2011, MED RADIOL DIAGN IMA, P1, DOI 10.1007/978-3-642-01740-7
[7]  
MILLNER M R, 1979, Medical Physics (Woodbury), V6, P70, DOI 10.1118/1.594555
[8]   Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: A phantom study [J].
Takahashi, Naoki ;
Hartman, Robert P. ;
Vrtiska, Terri J. ;
Kawashima, Akira ;
Primak, Andrew N. ;
Dzyubak, Oleksandr P. ;
Mandrekar, Jayawant N. ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) :1169-1173
[9]   Soft tissue discrimination ex vivo by dual energy computed tomography [J].
Zachrisson, H. ;
Engstrom, E. ;
Engvall, J. ;
Wigstrom, L. ;
Smedby, O. ;
Persson, A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) :E124-E128