Saturation Recovery Myocardial T1 Mapping with a Composite Radiofrequency Pulse on a 3T MR Imaging System

被引:5
作者
Morita, Kosuke [1 ]
Oda, Seitaro [2 ]
Utsunomiya, Daisuke [2 ]
Nakaura, Takeshi [2 ]
Matsubara, Takatoshi [1 ]
Goto, Makoto [1 ]
Okuaki, Tomoyuki [3 ]
Yuki, Hideaki [2 ]
Nagayama, Yasunori [2 ]
Kidoh, Masafumi [2 ]
Hirata, Kenichiro [2 ]
Iyama, Yuij [2 ]
Taguchi, Narumi [2 ]
Hatemura, Masahiro [1 ]
Hashida, Masahiro [1 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Kumamoto Univ Hosp, Dept Cent Radiol, Kumamoto, Kumamoto, Japan
[2] Kumamoto Univ, Fac Life Sci, Dept Diagnost Radiol, Chuo Ku, 1-1-1 Honjyo, Kumamoto, Kumamoto 8608556, Japan
[3] Philips Elect Japan, MR Clin Sci, Tokyo, Japan
关键词
myocardial T-1 mapping; saturation recovery; composite radio-frequency pulse; reproducibility; 3T magnetic resonance; CARDIOVASCULAR MAGNETIC-RESONANCE; T1; MOLLI; HEART; RESOLUTION; SHMOLLI; REPRODUCIBILITY; SPECTROSCOPY; SEQUENCES; ACCURACY;
D O I
10.2463/mrms.mp.2016-0092
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effect of a composite radiofrequency (RF) pulse on saturation recovery (SR) myocardial T-1 mapping using a 3T MR system. Materials and Methods: Phantom and in vivo studies were performed with a clinical 3T MR scanner. Accuracy and reproducibility of the SR T-1 mapping using conventional and composite RF pulses were first compared in phantom experiments. An in vivo study was performed of 10 healthy volunteers who were imaged with conventional and composite RF pulse methods twice each. In vivo reproducibility of myocardial T-1 value and the inter-segment variability were assessed. Results: The phantom study revealed significant differences in the mean T-1 values between the two methods, and the reproducibility for the composite RF pulse was significantly smaller than that for the conventional RF pulse. For both methods, the correlations of the reference and measured T-1 values were excellent (r(2) = 0.97 and 0.98 for conventional and composite RF pulses, respectively). The in vivo study showed that the mean T-1 value for composite RF pulse was slightly lower than that for conventional RF pulse, but this difference was not significant (P = 0.06). The inter-segment variability for the composite RF pulse was significantly smaller than that for conventional RF pulse (P < 0.01). Inter-scan correlations of T-1 measurements of the first and second scans were highly and weakly correlated to composite RF pulses (r = 0.83 and 0.29, respectively). Conclusion: SR T-1 mapping using composite RF pulse provides accurate quantification of T-1 values and can lessen measurement variability and enable reproducible T-1 measurements.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 28 条
[1]   Myocardial T1 Mapping - Hope or Hype? [J].
Bulluck, Heerajnarain ;
Maestrini, Viviana ;
Rosmini, Stefania ;
Abdel-Gadir, Amna ;
Treibel, Thomas A. ;
Castelletti, Silvia ;
Bucciarelli-Ducci, Chiara ;
Manisty, Charlotte ;
Moon, James C. .
CIRCULATION JOURNAL, 2015, 79 (03) :487-494
[2]   Saturation pulse design for quantitative myocardial T1 mapping [J].
Chow, Kelvin ;
Kellman, Peter ;
Spottiswoode, Bruce S. ;
Nielles-Vallespin, Sonia ;
Arai, Andrew E. ;
Salerno, Michael ;
Thompson, Richard B. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[3]   Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping [J].
Chow, Kelvin ;
Flewitt, Jacqueline A. ;
Green, Jordin D. ;
Pagano, Joseph J. ;
Friedrich, Matthias G. ;
Thompson, Richard B. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) :2082-2095
[4]   Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarction [J].
Dall'Armellina, Erica ;
Piechnik, Stefan K. ;
Ferreira, Vanessa M. ;
Si, Quang Le ;
Robson, Matthew D. ;
Francis, Jane M. ;
Cuculi, Florim ;
Kharbanda, Rajesh K. ;
Banning, Adrian P. ;
Choudhury, Robin P. ;
Karamitsos, Theodoros D. ;
Neubauer, Stefan .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
[5]   Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance [J].
Ferreira, Vanessa M. ;
Piechnik, Stefan K. ;
Dall'Armellina, Erica ;
Karamitsos, Theodoros D. ;
Francis, Jane M. ;
Choudhury, Robin P. ;
Friedrich, Matthias G. ;
Robson, Matthew D. ;
Neubauer, Stefan .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
[6]   Arrhythmia Insensitive Rapid Cardiac T1 Mapping Pulse Sequence [J].
Fitts, Michelle ;
Breton, Elodie ;
Kholmovski, Eugene G. ;
Dosdall, Derek J. ;
Vijayakumar, Sathya ;
Hong, Kyung P. ;
Ranjan, Ravi ;
Marrouche, Nassir F. ;
Axel, Leon ;
Kim, Daniel .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (05) :1274-1282
[7]   LOCALIZED HIGH-RESOLUTION PROTON NMR-SPECTROSCOPY USING STIMULATED ECHOES - INITIAL APPLICATIONS TO HUMAN-BRAIN INVIVO [J].
FRAHM, J ;
BRUHN, H ;
GYNGELL, ML ;
MERBOLDT, KD ;
HANICKE, W ;
SAUTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :79-93
[8]   Pulsed star labeling of arterial regions (PULSAR): A robust regional perfusion technique for high field imaging [J].
Golay, X ;
Petersen, ET ;
Hui, F .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :15-21
[9]   Mapping the Future of Cardiac MR Imaging: Case-based Review of T1 and T2 Mapping Techniques [J].
Hamlin, Scott A. ;
Henry, Travis S. ;
Little, Brent P. ;
Lerakis, Stamatios ;
Stillman, Arthur E. .
RADIOGRAPHICS, 2014, 34 (06) :1594-1611
[10]   Adiabatic Inversion Pulses for Myocardial T1 Mapping [J].
Kellman, Peter ;
Herzka, Daniel A. ;
Hansen, Michael Schacht .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) :1428-1434