Comparison of HR-pQCT- and microCT-based finite element models for the estimation of the mechanical properties of the calcaneus trabecular bone

被引:10
作者
Alsayednoor, J. [1 ]
Metcalf, L. [2 ]
Rochester, J. [3 ]
Dall'Ara, E. [4 ,5 ]
McCloskey, E. [2 ,4 ,5 ]
Lacroix, D. [1 ]
机构
[1] Univ Sheffield, Dept Mech Engn, INSIGNEO Inst Sil Med, Mappin St, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Sheffield, Dept Oncol & Metab, MRC Arthrit UK Ctr Integrated Res Musculoskeletal, Sheffield, S Yorkshire, England
[3] Univ Sheffield, Med Sch, Acad Unit Med Educ, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Dept Oncol & Metab, Sheffield, S Yorkshire, England
[5] Univ Sheffield, INSIGNEO Inst Sil Med, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
In vivo assessment; Trabecular microstructure; Finite element model; HR-pQCT; Trabecular segmentation; Calcaneus; QUANTITATIVE COMPUTED-TOMOGRAPHY; DISTAL RADIUS; TOPOLOGICAL ANALYSIS; ELASTIC-MODULUS; MICROARCHITECTURE; PLATES; STRENGTH; IMAGES; RODS; CLASSIFICATION;
D O I
10.1007/s10237-018-1051-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The calcaneus bone is formed of extensive trabecular bone and is therefore well suited to be used as an example of loaded bone to establish the ability of combining microfinite element (microFE) technique with high-resolution peripheral quantitative computed tomography (HR-pQCT) in determining its mechanical properties. HR-pQCT is increasingly used as a tool for in vivo bone clinical research, but its use has been limited to the distal radius and tibia. The goal of this study was to determine the applicability of HR-pQCT-derived microFE models of the calcaneus trabecular bone with 82m voxel size with reference to higher-resolution microCT-based models taken as gold standard. By comparing the outputs of microFE models generated from both HR-pQCT and microCT images of the trabecular bone of five calcaneus cadaveric specimens, it was found that the HR-pQCT-based models predicted mechanical properties for fracture load, total reaction force and von Mises stress are considerably different from microCT-based counterparts by 33, 64 and 70%, respectively. Also, the morphological analysis showed a comprehensive geometrical difference between HR-pQCT-based microFE models and their microCT-based equivalents. The results of the HR-pQCT-based models were found to have strong dependency on the threshold value chosen to binarise the images prior to finite element modelling. In addition, it was found that the voxel size has a strong impact on accuracy of imaged-based microFE models compared to other factors such as the presence of soft tissue and image scanning integration time. Therefore, although HR-pQCT has shown to be useful to predict overall structural and biomechanical changes, it is limited in providing local accurate biomechanical properties of trabecular bone and therefore should be used with caution when assessing bone remodelling through local changes of trabecular bone apposition and resorption in disease treatment monitoring.
引用
收藏
页码:1715 / 1730
页数:16
相关论文
共 41 条
  • [1] Assessment of 2D and 3D fractal dimension measurements of trabecular bone from high-spatial resolution magnetic resonance images at 3 T
    Alberich-Bayarri, Angel
    Marti-Bonmati, Luis
    Angeles Perez, Maria
    Sanz-Requena, Roberto
    Jose Lerma-Garrido, Juan
    Garcia-Marti, Gracian
    Morata, David
    [J]. MEDICAL PHYSICS, 2010, 37 (09) : 4930 - 4937
  • [2] [Anonymous], 2015, K WAVE MATLAB TOOLBO
  • [3] Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution
    Bevill, Grant
    Keaveny, Tony M.
    [J]. BONE, 2009, 44 (04) : 579 - 584
  • [4] Finite element analysis based on in vivo HR-pQCT images of the distal radius is associated with wrist fracture in postmenopausal women
    Boutroy, Stephanie
    Van Rietbergen, Bert
    Sornay-Rendu, Elisabeth
    Munoz, Francoise
    Bouxsein, Mary L.
    Delmas, Pierre D.
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 (03) : 392 - 399
  • [5] A local adaptive threshold strategy for high resolution peripheral quantitative computed tomography of trabecular bone
    Burghardt, Andrew J.
    Kazakia, Galateia J.
    Majumdar, Sharmila
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (10) : 1678 - 1686
  • [6] Voxel size dependency, reproducibility and sensitivity of an in vivo bone loading estimation algorithm
    Christen, Patrik
    Schulte, Friederike A.
    Zwahlen, Alexander
    van Rietbergen, Bert
    Boutroy, Stephanie
    Melton, L. Joseph, III
    Amin, Shreyasee
    Khosla, Sundeep
    Goldhahn, Jorg
    Mueller, Ralph
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2016, 13 (114)
  • [7] Finite element dependence of stress evaluation for human trabecular bone
    Depalle, B.
    Chapurlat, R.
    Walter-Le-Berre, H.
    Bou-Said, B.
    Follet, H.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 18 : 200 - 212
  • [8] Accuracy of cancellous bone volume fraction measured by micro-CT scanning
    Ding, M
    Odgaard, A
    Hvid, I
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (03) : 323 - 326
  • [9] Morphology based anisotropic finite element models of the proximal femur validated with experimental data
    Enns-Bray, W. S.
    Ariza, O.
    Gilchrist, S.
    Soyka, R. P. Widmer
    Vogt, P. J.
    Palsson, H.
    Boyd, S. K.
    Guy, P.
    Cripton, P. A.
    Ferguson, S. J.
    Helgason, B.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2016, 38 (11) : 1339 - 1347
  • [10] Skeletal changes through the lifespan-from growth to senescence
    Farr, Joshua N.
    Khosla, Sundeep
    [J]. NATURE REVIEWS ENDOCRINOLOGY, 2015, 11 (09) : 513 - 521