An enzyme immunoanalytical system based on sequential cross-flow chromatography

被引:46
作者
Cho, JH
Paek, EH
Cho, IH
Paek, SH
机构
[1] Korea Univ, BioDigit Labs Corp, Sungbuk Ku, Seoul 136701, South Korea
[2] Korea Univ, Program Biomicrosyst Technol, Sungbuk Ku, Seoul 136701, South Korea
[3] Korea Univ, Dept Biotechnol, Chungnam 339800, South Korea
关键词
D O I
10.1021/ac048270d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new enzyme immunoanalytical concept that can be used for point-of-care testing has been investigated. Enzyme as a tracer requires a separate reaction step for signal generation, which follows the completion of immune complex formation with analyte (e.g., Hepatitis B surface antigen) in a sample. Ibis has been a major factor limiting its utilization within the laboratory. We carried out such sequential processes employing chromatographic analysis, using two crosswise-arranged membrane pads in vertical and horizontal directions. The vertically arranged pads were the same as those in the usual format for pregnancy testing, for instance, with the exception of the use of horseradish peroxidase (HRP) as tracer. By placing the horizontally arranged pads on each lateral side of the signal generation pad in the vertical arrangement, they were employed to supply substrate to the enzyme present in the immune complexes. The substrate flow was initiated after the antigen-antibody bindings to produce a signal, which was typically a color change in proportion to the analyte concentration. Under optimal conditions, the use of HRP labeling increased the detection capability of the assay similar to 30 times compared to that of gold colloids. Potential advantages of using the concept investigated are (1) provision of a rapid and simple immunoassay, (2) satisfaction of a clinical need for highly sensitive determination of analyte, and (3) utilization of relatively inexpensive, portable quantitation means.
引用
收藏
页码:4091 / 4097
页数:7
相关论文
共 32 条
[1]  
ALBERT RM, 1993, PAWLEY IMMUNOCYTOCHE, P151
[2]   Point-of-care testing of cardiac markers: results from an experience in an Emergency Department [J].
Altinier, S ;
Zaninotto, M ;
Mion, M ;
Carraro, P ;
Rocco, S ;
Tosato, F ;
Plebani, M .
CLINICA CHIMICA ACTA, 2001, 311 (01) :67-72
[3]  
Apple FS, 1999, CLIN CHEM, V45, P199
[4]  
Centola GM, 1997, AM J REPROD IMMUNOL, V37, P300
[5]   Semiquantitative, bar code version of immunochromatographic assay system for human serum albumin as model analyte [J].
Cho, JH ;
Paek, SH .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 75 (06) :725-732
[6]   A rapid, simple measurement of human albumin in whole blood using a fluorescence immunoassay (I) [J].
Choi, S ;
Choi, EY ;
Kim, DJ ;
Kim, JH ;
Kim, TS ;
Oh, SW .
CLINICA CHIMICA ACTA, 2004, 339 (1-2) :147-156
[7]  
CHRISTOPER PP, 1997, PRINCIPLES PRACTICE, P13
[8]  
Collinson PO, 1999, SCAND J CLIN LAB INV, V59, P67
[9]  
DONALD RH, 2001, J IMMUNOL METHODS, V249, P33
[10]  
Dykman LA, 1998, COLLOID J+, V60, P700