Chromatographic behaviour of phenylurea herbicides and phenols on a silica gel column with ternary gradient elution using mobile phases containing dry 2-propanol, n-heptane and dioxane was investigated. With dried solvents and the temperature controlled to +/-0.01 degrees C, the data from repeated experiments measured on the same column after ten months of use were reproducible. Algorithms were suggested for characterization and prediction of retention in ternary gradients at a constant ratio of the two polar solvents (elution strength gradients) and at a constant sum of their concentrations (selectivity gradients). These were based on two- and three-parameter equations describing the dependence of the sample retention factors (isocratic) on the concentration of the polar solvent in binary mobile phases.