A Monte Carlo study on tissue dose enhancement in brachytherapy: a comparison between gadolinium and gold nanoparticles

被引:40
作者
Toossi, Mohammad Taghi Bahreyni [2 ]
Ghorbani, Mahdi [1 ]
Mehrpouyan, Mohammad [2 ]
Akbari, Fateme [2 ]
Sabet, Leila Sobhkhiz [2 ]
Meigooni, Ali Soleimani [3 ]
机构
[1] N Khorasan Univ Med Sci, Bojnurd 9414953535, N Khorasan, Iran
[2] Mashhad Univ Med Sci, Fac Med, Dept Med Phys, Med Phys Res Ctr, Mashhad, Iran
[3] Comprehens Canc Ctr Nevada, Las Vegas, NV USA
关键词
Brachytherapy; Dose enhancement; Monte Carlo simulation; Gadolinium nanoparticles; Gold nanoparticles; RADIATION; DOSIMETRY; ENERGY; SIMULATION; THERAPY;
D O I
10.1007/s13246-012-0143-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to quantify the dose enhancement by gadolinium and gold nanoparticles in brachytherapy. MCNPX Monte Carlo code was used to simulate four brachytherapy sources: Co-60, Au-198, Ir-192, Yb-169. To verify the accuracy of our simulations, the obtained values of dose rate constants and radial dose functions were compared with corresponding published values for these sources. To study dose enhancements, a spherical soft tissue phantom with 15 cm in radius was simulated. Gadolinium and gold nanoparticles at 10, 20 and 30 mg/ml concentrations were separately assumed in a 1 x 1 x 1 cm(3) volume simulating tumour. The simulated dose to the tumour with the impurity was compared to the dose without impurity, as a function of radial distance and concentration of the impurity, to determine the enhancement of dose due to the presence of the impurity. Dose enhancements in the tumour obtained in the presence of gadolinium and gold nanoparticles with concentration of 30 mg/ml, were found to be in the range of -0.5-106.1 and 0.4-153.1 % respectively. In addition, at higher radial distances from the source center, higher dose enhancements were observed. GdNPs can be used as a high atomic number material to enhance dose in tumour volume with dose enhancements up to 106.1 % when used in brachytherapy. Regardless considering the clinical limitations of the here-in presented model, for a similar source and concentration of nanoparticles, gold nanoparticles show higher dose enhancement than gadolinium nanoparticles and can have more clinical usefulness as dose enhancer material.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 27 条
  • [21] Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    Rivard, MJ
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Huq, MS
    Ibbott, GS
    Mitch, MG
    Nath, R
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 633 - 674
  • [22] Generation and modelling of megavoltage photon beams for contrast-enhanced radiation therapy
    Robar, J. L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21) : 5487 - 5504
  • [23] Monte Carlo modeling of Co-60 HDR brachytherapy source in water and in different solid water phantom materials
    Sahoo, S.
    Selvam, T. Palani
    Vishwakarma, R. S.
    Chourasiya, G.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2010, 35 (01) : 15 - 22
  • [24] Air kerma strength characterization of a GZP6 Cobalt-60 brachytherapy source
    Toossi, Mohammad Taghi Bahreyni
    Ghorbani, Mandi
    Mowlavi, Ali Asghar
    Taheri, Mojtaba
    Layegh, Mohsen
    Makhdoumi, Yasha
    Meigooni, Ali Soleimani
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2010, 15 (06) : 190 - 194
  • [25] Beam energy considerations for gold nano-particle enhanced radiation treatment
    Van den Heuvel, F.
    Locquet, Jean-Pierre
    Nuyts, S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) : 4509 - 4520
  • [26] MONTE-CARLO AIDED DOSIMETRY OF THE MICROSELECTRON PULSED AND HIGH-DOSE-RATE IR-192 SOURCES
    WILLIAMSON, JF
    LI, ZF
    [J]. MEDICAL PHYSICS, 1995, 22 (06) : 809 - 819
  • [27] Quantifying tumor-selective radiation dose enhancements using gold nanoparticles: a monte carlo simulation study
    Zhang, Sean X.
    Gao, Junfang
    Buchholz, Thomas A.
    Wang, Zhonglu
    Salehpour, Mohammad R.
    Drezek, Rebekah A.
    Yu, Tse-Kuan
    [J]. BIOMEDICAL MICRODEVICES, 2009, 11 (04) : 925 - 933