Use of Oxidized Zirconium Hemiarthroplasty in Hip Fractures

被引:9
作者
Sah, Alexander P. [1 ]
Ready, John E. [2 ]
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed, Boston, MA 02114 USA
[2] Brigham & Womens Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
关键词
zirconium; hemiarthroplasty; spectrum analysis;
D O I
10.1016/j.arth.2006.10.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Oxidized zirconium may have improved wear characteristics against polyethylene, but its performance against native cartilage is unknown. Between 1996 and 1998, 52 patients received an oxidized zirconium hemiarthroplasty for the treatment of a hip fracture. Twelve patients (23%) died within I year of surgery, and 24 (46%) were surviving at 5 years. In 38 patients with minimum 2-years follow-up, clinical evaluation after surgery averaged 4.5 years with Harris hip scores averaging 78 (range, 55-92). Three patients radiographically showed acetabular protrusion or significant wear, with 2 undergoing revision surgery. An explanted prosthesis demonstrated no appreciable damage by spectrum analysis. Because of the high mortality rate after hip fracture, the clinical benefits of oxidized zirconium hemiarthroplasty in this population, if existent, are difficult to appreciate and Currently show no benefits over standard prostheses.
引用
收藏
页码:1174 / 1180
页数:7
相关论文
共 44 条
[1]   Poor eight-year survival of cemented zirconia-polyethylene total hip replacements [J].
Allain, J ;
Le Mouel, S ;
Goutallier, D ;
Voisin, MC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :835-842
[2]   Cementless bipolar hemiarthroplasty for displaced femoral neck fractures in the elderly [J].
Bezwada, HP ;
Shah, AR ;
Harding, SH ;
Baker, J ;
Johanson, NA ;
Mont, MA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :73-77
[3]   Internal fixation compared with arthroplasty for displaced fractures of the femoral neck - A meta-analysis [J].
Bhandari, M ;
Devereaux, PJ ;
Swiontkowski, MF ;
Tornetta, P ;
Obremskey, W ;
Koval, KJ ;
Nork, S ;
Sprague, S ;
Schemitsch, EH ;
Guyatt, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (09) :1673-1681
[4]   Arthroplasty options for the young patient [J].
Bourne, RB ;
Barrack, R ;
Rorabeck, CH ;
Salehi, A ;
Good, V .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :159-167
[5]   Zirconia as a sliding material -: Histologic, laboratory, and clinical data [J].
Cales, B .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (379) :94-112
[6]   Current status of zirconia used in total hip implants [J].
Clarke, IC ;
Manaka, M ;
Green, DD ;
Williams, P ;
Pezzotti, G ;
Kim, YH ;
Ries, M ;
Sugano, N ;
Sedel, L ;
Delauney, C ;
Ben Nissan, B ;
Donaldson, T ;
Gustafson, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :73-84
[7]  
Drouin JM, 1997, J BIOMED MATER RES, V34, P149, DOI 10.1002/(SICI)1097-4636(199702)34:2<149::AID-JBM2>3.0.CO
[8]  
2-Q
[9]  
EISKJAER S, 1993, CLIN ORTHOP RELAT R, V286, P206
[10]   PELVIC STRESSES INVITRO .1. MALSIZING OF ENDOPROSTHESES [J].
FINLAY, JB ;
BOURNE, RB ;
LANDSBERG, RPD ;
ANDREAE, P .
JOURNAL OF BIOMECHANICS, 1986, 19 (09) :703-714