Comparing lateral flow testing with a rapid RT-PCR method for SARS-CoV-2 detection in the United Kingdom-A retrospective diagnostic accuracy study

被引:3
作者
Taylor, Andrew [1 ]
Calvez, Ronan [1 ]
Atkins, Mark [1 ]
Fink, Colin G. [1 ,2 ]
机构
[1] Micropathology Ltd, Venture Ctr, Univ Warwick Sci Pk,Sir William Lyons Rd, Coventry CV4 7EZ, W Midlands, England
[2] Univ Warwick, Coventry, W Midlands, England
基金
英国科研创新办公室;
关键词
diagnostics; lateral flow; RT-PCR; SARS-CoV-2; sensitivity;
D O I
10.1002/hsr2.811
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background and Aims In late 2019, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged in Wuhan, China. Rapid global spread led to the coronavirus disease 2019 (Covid-19) pandemic. Accurate detection of SARS-CoV-2 has become a vitally important tool in controlling the spread of the virus. Lateral flow devices (LFDs) offer the potential advantage of speed and on-site testing. The sensitivity of these devices compared to reverse transcription-polymerase chain reaction (RT-PCR) has been questioned. Methods We compared the sensitivity of the Innova LFD, used widely in the United Kingdom, with our rapid RT-PCR method using stored positive samples. Samples with a range of viral loads (original Ct values 18.9-36.5) were tested. Results The Innova LFD was found to be 6000-10,000 times less sensitive than RT-PCR for SARS-CoV-2 detection. Overall, the LFD detected 46.2% of the positives detected by RT-PCR, with 50% of these observed to be weak LFD positives. At lower viral loads, such as 10,000-100,000 RNA copies/ml, the LFD detected 22.2% of positives. In addition, two strong positives (3 and 1.5 million RNA copies/ml) were not detected by the LFD. Conclusion The argument for use of LFD kits is that they detect infectious virus and hence contagious individuals. However, there is a lack of conclusive evidence supporting this claim. The Innova LFD has been subject to a Class I recall by the US Food and Drug Administration, but is still approved and widely used in the United Kingdom.
引用
收藏
页数:7
相关论文
共 25 条
  • [1] [Anonymous], 2021, Weekly epidemiological update on COVID-19-20 April 2021, V46th
  • [2] Molecular detection of SARS-CoV-2 using a reagent-free approach
    Calvez, Ronan
    Taylor, Andrew
    Calvo-Bado, Leonides
    Fraser, Donald
    Fink, Colin G.
    [J]. PLOS ONE, 2020, 15 (12):
  • [3] Implementing SARS-CoV-2 Rapid Antigen Testing in the Emergency Ward of a Swiss University Hospital: The INCREASE Study
    Caruana, Giorgia
    Croxatto, Antony
    Kampouri, Eleftheria
    Kritikos, Antonios
    Opota, Onya
    Foerster, Maryline
    Brouillet, Rene
    Senn, Laurence
    Lienhard, Reto
    Egli, Adrian
    Pantaleo, Giuseppe
    Carron, Pierre-Nicolas
    Greub, Gilbert
    [J]. MICROORGANISMS, 2021, 9 (04)
  • [4] CDC, 2020, RES US ONL 2019 NOV
  • [5] Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR (Publication with Expression of Concern)
    Corman, Victor M.
    Landt, Olfert
    Kaiser, Marco
    Molenkamp, Richard
    Meijer, Adam
    Chu, Daniel K. W.
    Bleicker, Tobias
    Bruenink, Sebastian
    Schneider, Julia
    Schmidt, Marie Luisa
    Mulders, Daphne G. J. C.
    Haagmans, Bart L.
    van der Veer, Bas
    van den Brink, Sharon
    Wijsman, Lisa
    Goderski, Gabriel
    Romette, Jean-Louis
    Ellis, Joanna
    Zambon, Maria
    Peiris, Malik
    Goossens, Herman
    Reusken, Chantal
    Koopmans, Marion P. G.
    Drosten, Christian
    [J]. EUROSURVEILLANCE, 2020, 25 (03) : 23 - 30
  • [6] Lateral flow tests cannot rule out SARS-CoV-2 infection People testing negative must stick to infection control recommendations
    Deeks, Jonathan J.
    Raffle, Angela E.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2020, 371
  • [7] England P.H.., 2020, PREL REP JOINT PHE P
  • [8] FDA, 2021, STOP US INN SARS COV
  • [9] The Digital MIQE Guidelines Update: Minimum Information for Publication of Quantitative Digital PCR Experiments for 2020
    Huggett, Jim F.
    Whale, Alexandra S.
    De Spiegelaere, Ward
    Nour, Afif Abdel
    Bae, Young-Kyung
    Benes, Vladimir
    Burke, Daniel
    Cleveland, Megan
    Corbisier, Philippe
    Devonshire, Alison S.
    Dong, Lianhua
    Drandi, Daniela
    Foy, Carole A.
    Garson, Jeremy A.
    He, Hua-Jun
    Hellemans, Jan
    Kubista, Mikael
    Lievens, Antoon
    Makrigiorgos, Mike G.
    Milavec, Mojca
    Mueller, Reinhold D.
    Nolan, Tania
    O'Sullivan, Denise M.
    Pfaffl, Michael W.
    Roediger, Stefan
    Romsos, Erica L.
    Shipley, Gregory L.
    Taly, Valerie
    Untergasser, Andreas
    Wittwer, Carl T.
    Bustin, Stephen A.
    Vandesompele, Jo
    [J]. CLINICAL CHEMISTRY, 2020, 66 (08) : 1012 - 1029
  • [10] Evaluation of three rapid lateral flow antigen detection tests for the diagnosis of SARS-CoV-2 infection
    Jaaskelainen, A. E.
    Ahava, M. J.
    Jokela, P.
    Szirovicza, L.
    Pohjala, S.
    Vapalahti, O.
    Lappalainen, M.
    Hepojoki, J.
    Kurkela, S.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2021, 137