Flake-Austin modification of the STA-peg arthroereisis - A retrospective study

被引:12
作者
Forg, P
Feldman, K
Flake, E
Green, DR
机构
[1] Scripps Mercy Hospital and Medical Center, San Diego, CA
[2] San Diego, CA 92103
关键词
D O I
10.7547/87507315-91-8-394
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Smith subtalar arthroereisis implant (STA-peg) is used to correct severe collapsing pes valgoplanus in children. Flake and Austin modified the placement of this implant to block the leading wall of the lateral talus. Twenty-one patients with a total of 40 STA-peg procedures were evaluated subjectively and objectively. The average age at the time of surgery was 9.7 years (4 to 16 years). The follow-up period averaged 36 months (12 to 90 months). The subjective, objective, and radiographic results were positive and the complication rate was low. A significant advantage of the Flake-Austin modification of the STA-peg placement in transverse planar dominant foot types is also noted.