Comparison between coronal reformatted images and direct coronal CT images of the swine lung specimen: assessment of image quality with 64-detector row CT

被引:6
作者
Choi, E. J. [1 ]
Oh, Y-W [1 ]
Ham, S. Y. [1 ]
Lee, K. Y. [1 ]
Kang, E-Y [1 ]
机构
[1] Korea Univ, Dept Radiol, Anam Hosp, Seoul, South Korea
关键词
D O I
10.1259/bjr/63217190
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aims of this study were to compare the image quality of coronal multiplanar reconstruction (MPR) images from axial spiral images with that of direct coronal spiral and sequential images, and to estimate and analyse the effect of an incremental change on the image quality using 64-detector row CT. 12 swine lungs were used. Five kinds of images from each lung specimen were obtained using 64-detector row CT. All images were analysed by categories and grades, and the direct coronal sequential images Were used as the reference standard for the image quality. Statistical analysis was performed for the following categories: (i) inter-observer reliability, (ii) interaction between the observers and images, (iii) image analysis, (iv) anatomical structural analysis of each observer, (v) stair-step artefact and (vi) background noise. The overall image quality and the image quality of all anatomical structures of coronal MPR images with 0.67 mm slice increments were inferior to the image quality of the other images; this difference was statistically significant (P<0.05). Stair-step artefact was detected on coronal MPR images, and was more prominent on coronal MPR images with 0.67 mm slice increments than on coronal MPR images with 0.34 mm slice increments. The most severe background noise was detected on the direct coronal sequential images, but there was no significant difference between the direct coronal sequential images and the direct coronal spiral images. Background noise was least prominent on coronal MPR images with 0.67 mm slice increments. The increment process is important for improving the image quality of MPR images even when using 64-detector row C-T. Coronal MPR images with 0.34 mm slice increments using 64-detector row CT showed a similar image quality to that obtained from the direct coronal images, and can be used instead. This means that the coronal MPR images obtained with 64-detector row CT could be as useful for evaluating the lung parenchyma as the axial high-resolution CT images.
引用
收藏
页码:463 / 467
页数:5
相关论文
共 23 条
[1]   Coronal thick CT reconstruction: An alternative for initial chest radiography in trauma patients [J].
Alkadhi H. ;
Baumert B. ;
Wildermuth S. ;
Bloch K.E. ;
Marincek B. ;
Boehm T. .
Emergency Radiology, 2005, 12 (1-2) :3-10
[2]   Comparison of axial high-resolution CT and thin-section multiplanar reformation (MPR) for diagnosis of diseases of the pulmonary parenchyma - Preliminary study in 49 patients [J].
Arakawa, H ;
Sasaka, K ;
Lu, WM ;
Hirayanagi, N ;
Nakajima, Y .
JOURNAL OF THORACIC IMAGING, 2004, 19 (01) :24-31
[3]   Value of multiplanar reformations (MPR) in multidetector CT (MDCT) of acute vertebral fractures - Do we still have to read the transverse images? [J].
Begemann, PGC ;
Kemper, J ;
Gatzka, C ;
Stork, A ;
Nolte-Ernsting, C ;
Adam, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (04) :572-580
[4]   Comparison of artifacts on coronal reformation and axial CT pulmonary angiography images using single-detector and 4-and 8-detector multidetector-row helical CT scanners [J].
Boiselle, PM ;
Hasegawa, I ;
Nishino, M ;
Raptopoulos, V ;
Hatabu, H .
ACADEMIC RADIOLOGY, 2005, 12 (05) :602-607
[5]   Appendix: Use of multidetector CT and three-dimensional reconstructions in thoracic outlet syndrome: a preliminary report [J].
Brantigan, CO ;
Johnston, RJ ;
Roos, DB .
HAND CLINICS, 2004, 20 (01) :123-+
[6]   CT cystography with multiplanar reformation for suspected bladder rupture: Experience in 234 cases [J].
Chan, David P. N. ;
Abujudeh, Hani H. ;
Cushing, George L., Jr. ;
Novelline, Robert A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (05) :1296-1302
[7]   High resolution volume imaging of airways and lung parenchyma with multislice CT [J].
Chooi, WK ;
Morcos, SK .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 :S98-S105
[8]  
Dawn S K, 2001, Respir Care, V46, P912
[9]   Value of multiplanar reformations (MPR) in multislice spiral CT. [J].
Eibel, R ;
Türk, T ;
Kulinna, C ;
Schöpf, UJ ;
Brüning, R ;
Reiser, MF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (01) :57-64
[10]   Stair-step artifacts with single versus multiple detector-row helical CT [J].
Fleischmann, D ;
Rubin, GD ;
Paik, DS ;
Yen, SY ;
Hilfiker, PR ;
Beaulieu, CF ;
Napel, S .
RADIOLOGY, 2000, 216 (01) :185-196