Analytical artifacts, sample handling and preservation methods of environmental samples of synthetic pyrethroids

被引:26
作者
Albaseer, Saeed S. [2 ]
Rao, R. Nageswara [1 ]
Swamy, Y. V. [3 ]
Mukkanti, K. [2 ]
机构
[1] Indian Inst Chem Technol, Div Analyt Chem, HPLC Grp, Hyderabad 500007, Andhra Pradesh, India
[2] INT Univ, Inst Sci & Technol, Ctr Chem Sci & Technol, Hyderabad 500085, Andhra Pradesh, India
[3] Indian Inst Chem Technol, Bioengn & Environm Ctr, Hyderabad 500007, Andhra Pradesh, India
关键词
Adsorption; Analytical artifact; Environmental analysis; Preservation; Sample handling; Soil analysis; Stability; Suspended particle; Synthetic pyrethroid; Water analysis; SOLID-PHASE MICROEXTRACTION; GAS-CHROMATOGRAPHIC ANALYSIS; LIQUID-CHROMATOGRAPHY; MULTIRESIDUE METHOD; LAMBDA-CYHALOTHRIN; PESTICIDE-RESIDUES; STORAGE-CONDITIONS; SUSPENDED-SOLIDS; WATER SAMPLES; PERMETHRIN;
D O I
10.1016/j.trac.2011.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sample handling and preservation methods of environmental samples of synthetic pyrethroids (SPs) are very important and must be controlled to maintain sample integrity during analytical determinations. However, published literature has treated this issue only partly, and, in many instances, with contradictory conclusions. The tendency of SPs to adsorb to varying degrees under different conditions - to surfaces and solid particulates with which they come in contact may be responsible for this situation. It has become evident that SPs discharged to water bodies are present mainly in the adsorbed state, and that affects their bioavailability and the reliability of analytical results. Refrigeration and storage in the dark are prerequisites for stabilization of SPs in environmental samples. Several other factors that contribute to SPs instability include: (1) matrix composition; (2) container material; and, (3) sample acidity. Sample agitation prior to analysis may be useful to reduce losses due to adsorption. There are several chemical reagents that inhibit the degradative processes of SPs, but the efficiency of preservation depends - to a large extent - on the characteristics of sample matrix. This article reviews various aspects related to preservation of SPs and puts forward a preliminary guideline for proper practice during sampling, storage and sample preparation of SPs. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1771 / 1780
页数:10
相关论文
共 62 条
[1]   An overview of sample preparation and extraction of synthetic pyrethroids from water, sediment and soil [J].
Albaseer, Saeed S. ;
Rao, R. Nageswara ;
Swamy, Y. V. ;
Mukkanti, K. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (35) :5537-5554
[2]   Sorption-desorption studies of six pyrethroids and mirex on soils using GC/MS-NICI [J].
Ali, MA ;
Baugh, PJ .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (11) :923-933
[3]  
Amelung W, 2007, J AOAC INT, V90, P1659
[4]   Evaluation of analyte protectants to improve gas chromatographic analysis of pesticides [J].
Anastassiades, M ;
Mastovská, K ;
Lehotay, SJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :163-184
[5]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[6]  
[Anonymous], 9883EC
[7]  
ATSDR, 2003, TOX PROF PYR PYR
[8]  
Bennett ER, 2000, B ENVIRON CONTAM TOX, V64, P825, DOI 10.1007/s001280000077
[9]   Analysis of pyrethroids in sediment pore water by solid-phase microextraction [J].
Bondarenko, Svetlana ;
Spurlock, Frank ;
Gan, Jianying .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2007, 26 (12) :2587-2593
[10]   AUTOMATED-DETERMINATION OF PYRETHROID INSECTICIDES IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY UV DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION [J].
BROUWER, ER ;
STRUYS, EA ;
VREULS, JJ ;
BRINKMAN, UAT .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (7-9) :487-495