The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty

被引:24
|
作者
Chiu, K. Y. [1 ]
Yau, W. P. [1 ]
Ng, T. P. [1 ]
Tang, W. M. [1 ]
机构
[1] Univ Hong Kong, Dept Orthoped & Traumatol, Div Joint Replacement Surg, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1007/s00264-007-0354-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Anteroposterior radiographs that included the whole tibia were taken before and after 75 total knee arthroplasties in 48 patients. The same tibial extra-medullary alignment guide system was used in every knee. The average tibial component alignment was 0.4 (SD 2.5, range -4.9 to 6.4) degrees of valgus post-operatively. 59 tibial components (78.7%) had a tibial cut within 3 degrees from being perpendicular to the mechanical axis, ten were too valgus (13.3%) and six were too varus (8%). The chance of the tibial components becoming too varus was higher if there was lateral tibial bowing, compared with no tibial bowing (p = 0.048). A smaller lateral width of the leg increased the chance of the tibial components becoming too valgus (p = 0.047).
引用
收藏
页码:467 / 471
页数:5
相关论文
共 50 条
  • [1] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    K. Y. Chiu
    W. P. Yau
    T. P. Ng
    W. M. Tang
    International Orthopaedics, 2008, 32 : 467 - 471
  • [2] A COMPARISON OF INTRAMEDULLARY AND EXTRAMEDULLARY ALIGNMENT SYSTEMS FOR TIBIAL COMPONENT PLACEMENT IN TOTAL KNEE ARTHROPLASTY
    BRYS, DA
    LOMBARDI, AV
    MALLORY, TH
    VAUGHN, BK
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (263) : 175 - 179
  • [3] Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty
    Yang, SH
    Liu, TK
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 1998, 97 (08) : 564 - 568
  • [4] Accuracy of the Tibial Component Alignment by Extramedullary System Using Simple Radiographic References in Total Knee Arthroplasty
    Cho, Jin-Ho
    Choi, Jun Young
    Lee, Sung-Sahn
    MEDICINA-LITHUANIA, 2022, 58 (09):
  • [5] Anterior tibial border as a landmark for extramedullary alignment guides for total knee arthroplasty in valgus knees
    Kawahara, Shinya
    Fukagawa, Shingo
    Murakami, Koji
    Iwamoto, Yukihide
    Banks, ScottA
    Matsuda, Shuichi
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (12) : 1897 - 1899
  • [6] Accuracy of the second metatarsal as a landmark for the extramedullary tibial cutting guide in total knee arthroplasty
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 2969 - 2974
  • [7] ACCURACY OF INTRAMEDULLARY VERSUS EXTRAMEDULLARY TIBIAL ALIGNMENT CUTTING SYSTEMS IN TOTAL KNEE ARTHROPLASTY
    TETER, KE
    BREGMAN, D
    COLWELL, CW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (321) : 106 - 110
  • [8] Accuracy of the second metatarsal as a landmark for the extramedullary tibial cutting guide in total knee arthroplasty
    Tadashi Tsukeoka
    Yoshikazu Tsuneizumi
    Tae Hyun Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2969 - 2974
  • [9] EXTRAMEDULLARY VERSUS INTRAMEDULLARY ALIGNMENT GUIDES IN TOTAL KNEE ARTHROPLASTY
    ISHII, Y
    OHMORI, G
    BECHTOLD, JE
    GUSTILO, RB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (318) : 167 - 175
  • [10] Tibial component rotation in total knee arthroplasty
    Feczko, Peter Z.
    Pijls, Bart G.
    van Steijn, Michael J.
    van Rhijn, Lodewijk W.
    Arts, Jacobus J.
    Emans, Peter J.
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17