Demagnetization Analysis of Additional Permanent Magnets in Salient-Pole Synchronous Machines With Damper Bars Under Sudden Short Circuits

被引:40
作者
Hosoi, Tatsuya [1 ]
Watanabe, Hiroya [1 ]
Shima, Kazuo [1 ]
Fukami, Tadashi [1 ]
Hanaoka, Ryoichi [1 ]
Takata, Shinzo [1 ]
机构
[1] Kanazawa Inst Technol, Dept Elect & Elect Engn, Kanazawa, Ishikawa 9218501, Japan
关键词
AC machines; demagnetization; eddy currents; electromagnetic transients; fault tolerance; finite element methods; magnetic analysis; magnetic flux leakage; permanent magnets (PMs); HYBRID; GENERATOR;
D O I
10.1109/TIE.2011.2159956
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To improve output performance of salient-pole synchronous machines, permanent-magnet-assisted salient-pole synchronous machines (PMa-SMs) that have permanent magnets (PMs) between the field poles were previously developed. The PM effect of increasing the output power and the terminal voltage has already been confirmed by finite element analysis (FEA) and experiments under steady states. In this paper, demagnetization in the PMs due to sudden three-phase short circuits is evaluated by FEA. The results show that irreversible demagnetization arises in the PMs of a PMa-SM with relatively smaller circumferential PM length. Effects of the PM shape and damper bars on the irreversible demagnetization are also investigated. The results show that making the PM shape a rectangle and adding damper bars on the outer surfaces of the PMs are effective to reduce the demagnetization, while increasing the number of the conventional damper bars is not effective.
引用
收藏
页码:2448 / 2456
页数:9
相关论文
共 26 条
[1]  
Amara Y, 2001, IEEE T IND APPL, V37, P1273, DOI 10.1109/28.952502
[2]  
[Anonymous], 2010, P ICEM ROM IT SEP 6, P1
[3]  
[Anonymous], 2000, JEC2130
[4]   Design, Analysis, and Control of a Hybrid Field-Controlled Axial-Flux Permanent-Magnet Motor [J].
Aydin, Metin ;
Huang, Surong ;
Lipo, Thomas A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (01) :78-87
[5]  
Boldea I., 2006, ELECT GENERATORS HDB
[6]  
Boldea I., 2006, ELECT GENERATORS HDB, P426
[7]   A Double excited synchronous machine for direct drive application - Design and prototype tests [J].
Fodorean, Daniel ;
Djerdir, Abdesslem ;
Viorel, Loan-Adrian ;
Miraoui, Abdellatif .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (03) :656-665
[8]   Steady-State Analysis of a Permanent-Magnet-Assisted Salient-Pole Synchronous Generator [J].
Fukami, Tadashi ;
Hayamizu, Takahito ;
Matsui, Yasuhiro ;
Shima, Kazuo ;
Hanaoka, Ryoichi ;
Takata, Shinzo .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (02) :388-393
[9]  
Henneberger G., 1994, ICEM 94. International Conference on Electrical Machines, P472
[10]  
*IEC, 2008, 600344 IEC