Simulation and prediction of electrooxidation removal of ammonia and its application in industrial wastewater effluent

被引:3
|
作者
Ding, Jing [1 ]
Gao, Qingwei [1 ]
Wang, Yuhan [1 ]
Zhao, Guanshu [1 ]
Wang, Kun [1 ]
Jiang, Junqiu [1 ]
Li, Junjing [2 ]
Zhao, Qingliang [1 ]
机构
[1] Harbin Inst Technol, Sch Environm, State Key Lab Urban Water Resources & Environm SK, Harbin, Peoples R China
[2] Tiangong Univ, Sch Environm Sci & Engn, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
ammonia; electrooxidation; flow field; industrial wastewater; simulation; LANDFILL LEACHATE; ELECTROCHEMICAL-OXIDATION; NITROGEN-REMOVAL; DISINFECTION; CHLORINE; SYSTEM; PRECIPITATION; MECHANISM; NITRATE; BDD;
D O I
10.1002/wer.1343
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A FLUENT software able to predict and assess the electrooxidation of ammonia from the simulation of ammonia concentration and flow field distribution was developed in this study. The flow field-based models of ammonia removal were simulated and modified through the experimental results. The parameter of reaction constant k is corrected to 0.00195, and the modified model fitted well with experimental values, with the error less than 4%. The electrode depth of 4 cm was assessed to be optimal for ammonia removal based on the comparison of the simulation results on ammonia concentration and flow field distribution. The prediction result applied in the industrial wastewater treatment indicated that complete could be achieved at 0.27 Ah/L, and about 50% of total nitrogen was removed at 0.8 Ah/L. About 7% of chloride ions were converted into inorganic by-products, indicating low biological toxicity and risk on environment. The energy consumption increased with the promotion of removal efficiency of total nitrogen, requiring 5.4 kWh/m(3) to remove 50% total nitrogen at 0.8 Ah/L. The results show the practicability and feasibility of this FLUENT software tool on the simulation and prediction of electrooxidation process, which can provide the simulation parameter settings for the subsequent application. Practitioner points A FLUENT software based on the simulation of ammonia concentration and flow field distribution was able to predict and assess ammonia electrooxidation. A modified model is provided with a rate constant k of 0.00195 and the distinction of 4% with experimental results. The optimal electrode depth was predicted to be 4 cm via the obtained model. Complete ammonia and about 50% of total nitrogen could be at 0.27 Ah/L and 0.8 Ah/L, receptively. About 7% of chloride ions were converted into inorganic by-products in industrial wastewater with high chloride.
引用
收藏
页码:51 / 60
页数:10
相关论文
共 50 条
  • [1] Removal of Ammonia from Wastewater Effluent by Chlorella Vulgaris
    Jinsoo Kim
    Bala P.Lingaraju
    Rachael Rheaume
    Joo-Youp Lee
    Kaniz F.Siddiqui
    TsinghuaScienceandTechnology, 2010, 15 (04) : 391 - 396
  • [2] Removal of ammonia from wastewater effluent by chlorella vulgaris
    Kim J.
    Lingaraju B.P.
    Rheaume R.
    Lee J.-Y.
    Siddiqui K.F.
    Tsinghua Science and Technology, 2010, 15 (04) : 391 - 396
  • [3] Preparation of microbial flocculant and its preliminary application on removal of ammonia in tannery effluent
    Zhao, Changqing
    Yang, Qinhuan
    Teng, Bo
    Chen, Wuyong
    Jiang, Li
    Wang, Yan
    Deng, Sisi
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 824 - +
  • [4] Hybrid electrooxidation and adsorption process for the removal of ammonia in low concentration chloride wastewater
    Ding, Jing
    Zhao, Qing-Liang
    Zhang, Jun
    Jiang, Jun-Qiu
    Li, Wei
    Yu, Hang
    Huang, Li-Kun
    Zhang, Yun-Shu
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (06) : 5098 - 5105
  • [5] Hybrid electrooxidation and adsorption process for the removal of ammonia in low concentration chloride wastewater
    Jing Ding
    Qing-Liang Zhao
    Jun Zhang
    Jun-Qiu Jiang
    Wei Li
    Hang Yu
    Li-Kun Huang
    Yun-Shu Zhang
    Environmental Science and Pollution Research, 2017, 24 : 5098 - 5105
  • [6] Presence of phenol in wastewater effluent and its removal: an overview
    Mohd, Ayaz
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (06) : 1362 - 1384
  • [7] Electrochemical disinfection and removal of ammonia nitrogen for the reclamation of wastewater treatment plant effluent
    Ding, Jing
    Zhao, Qing-Liang
    Jiang, Jun-Qiu
    Wei, Liang-Liang
    Wang, Kun
    Zhang, Yun-Shu
    Hou, Wei-Zhu
    Yu, Hang
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (06) : 5152 - 5158
  • [8] Electrochemical disinfection and removal of ammonia nitrogen for the reclamation of wastewater treatment plant effluent
    Jing Ding
    Qing-Liang Zhao
    Jun-Qiu Jiang
    Liang-Liang Wei
    Kun Wang
    Yun-Shu Zhang
    Wei-Zhu Hou
    Hang Yu
    Environmental Science and Pollution Research, 2017, 24 : 5152 - 5158
  • [9] Simulation of ammonia removal from industrial wastewater streams by means of a hollow-fiber membrane contactor
    Rezakazemi, Mashallah
    Shirazian, Saeed
    Ashrafizadeh, Seyed Nezameddin
    DESALINATION, 2012, 285 : 383 - 392
  • [10] Modified methods of zeolite and its application of ammonia removal for residential area wastewater treatment
    Zuo, Jinlong
    2ND INTERNATIONAL SYMPOSIUM ON AQUA SCIENCE, WATER RESOURCE AND LOW CARBON ENERGY, 2010, 1251 : 288 - 291