Automation of Monte Carlo-based treatment plan verification for proton therapy

被引:8
|
作者
Kaluarachchi, Maduka [1 ]
Moskvin, Vadim [1 ]
Pirlepesov, Fakhriddin [1 ]
Wilson, Lydia J. [1 ]
Xie, Fang [1 ]
Faught, Austin M. [1 ]
机构
[1] St Jude Childrens Res Hosp, Dept Radiat Oncol, 332 N Lauderdale St, Memphis, TN 38105 USA
来源
关键词
automation; Monte Carlo; proton therapy; BRAIN-STEM; BRAGG PEAK; SIMULATION; HETEROGENEITIES; PARAMETERS; TOPAS;
D O I
10.1002/acm2.12923
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Independent calculations of proton therapy plans are an important quality control procedure in treatment planning. When using custom Monte Carlo (MC) models of the beamline, deploying the calculations can be laborious, time consuming, and require in-depth knowledge of the computational environment. We developed an automated framework to remove these barriers and integrate our MC model into the clinical workflow. Materials and Methods The Eclipse Scripting Application Programming Interface was used to initiate the automation process. A series of MATLAB scripts were then used for preprocessing of input data and postprocessing of results. Additional scripts were used to monitor the calculation process and appropriately deploy calculations to an institutional high-performance computing facility. The automated framework and beamline models were validated against 160 patient specific QA measurements from an ionization chamber array and using a +/- 3%/3 mm gamma criteria. Results The automation reduced the human-hours required to initiate and run a calculation to 1-2 min without leaving the treatment planning system environment. Validation comparisons had an average passing rate of 99.4% and were performed at depths ranging from 1 to 15 cm. Conclusion An automated framework for running MC calculations was developed which enables the calculation of dose and linear energy transfer within a clinically relevant workflow and timeline. The models and framework were validated against patient specific QA measurements and exhibited excellent agreement. Before this implementation, execution was prohibitively complex for an untrained individual and its use restricted to a research environment.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [41] Monte Carlo-Based Optimization for Lung SBRT Treatment Planning
    Zhong, H.
    Li, H.
    -Hurst, C. Glide
    Wen, N.
    Siebers, J.
    Nurushev, T.
    Chetty, I.
    MEDICAL PHYSICS, 2011, 38 (06) : 3648 - +
  • [42] Development and validation of MCNPX-based Monte Carlo treatment plan verification system
    Jabbari, Iraj
    Monadi, Shahram
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (02) : 80 - 89
  • [43] Full Monte Carlo-Based Biologic Treatment Plan Optimization System for Intensity Modulated Carbon Ion Therapy on Graphics Processing Unit
    Qin, Nan
    Shen, Chenyang
    Tsai, Min-Yu
    Pinto, Marco
    Tian, Zhen
    Dedes, Georgios
    Pompos, Arnold
    Jiang, Steve B.
    Parodi, Katia
    Jia, Xun
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01): : 235 - 243
  • [44] Monte Carlo framework for commissioning a synchrotron-based discrete spot scanning proton beam system and treatment plan verification
    Moskvin, Vadim P.
    Faught, Austin
    Pirlepesov, Fakhriddin
    Zhao, Li
    Hua, Chia-Ho
    Merchant, Thomas E.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04)
  • [45] Dosimetric verification of a Monte Carlo treatment planning system for MR-guided proton therapy
    Fuchs, H.
    Padilla-Cabal, F.
    Oborn, B.
    Traneus, E.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1544 - S1545
  • [46] Clinically Applicable Monte Carlo-based Biological Dose Optimization for the Treatment of Head and Neck Cancers With Spot-Scanning Proton Therapy
    Tseung, Hok Seum Wan Chan
    Ma, Jiasen
    Kreofsky, Cole R.
    Ma, Daniel J.
    Beltran, Chris
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (05): : 1535 - 1543
  • [47] Plan Verification using Monte Carlo Simulation
    Ludemann, L.
    Fuelhs, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (SUPPL 1) : S117 - S117
  • [48] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [49] Monte Carlo-based dose calculation engine for minibeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Prezado, Y.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 57 - 62
  • [50] A new approach to integrate GPU-based Monte Carlo simulation into inverse treatment plan optimization for proton therapy
    Li, Yongbao
    Tian, Zhen
    Song, Ting
    Wu, Zhaoxia
    Liu, Yaqiang
    Jiang, Steve
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01): : 289 - 305