Organophosphate triesters in indoor environments

被引:89
作者
Staaf, T [1 ]
Ostman, C [1 ]
机构
[1] Stockholm Univ, Dept Analyt Chem, SE-10691 Stockholm, Sweden
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2005年 / 7卷 / 09期
关键词
D O I
10.1039/b506631j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study the occurrence of ten organophosphate triesters in indoor air at 29 different locations was investigated. They were detected at all locations and a total of ten compounds were identified. The predominant compounds were the chlorinated compounds tris( chloroisopropyl) phosphate and tris(2-chloroethyl) phosphate with a concentration around 2 mu g m(-3) in some indoor environments. A rough estimation gives at hand a daily inhalation of around 10 mu g for each of these two compounds.
引用
收藏
页码:883 / 887
页数:5
相关论文
共 12 条
[1]   Toxicological evaluation and classification of the genotoxic, carcinogenic, reprotoxic and sensitising potential of tris(2-chloroethyl)phosphate [J].
Beth-Hübner, M .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1999, 72 (Suppl 3) :M17-M23
[2]   ALLERGIC CONTACT-DERMATITIS FROM TRIPHENYL PHOSPHATE [J].
CAMARASA, JG ;
SERRABALDRICH, E .
CONTACT DERMATITIS, 1992, 26 (04) :264-265
[3]   Video display units: An emission source of the contact allergenic flame retardant triphenyl phosphate in the indoor environment [J].
Carlsson, H ;
Nilsson, U ;
Ostman, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (18) :3885-3889
[4]   Organophosphate ester flame retardants and plasticizers in the indoor environment: Analytical methodology and occurrence [J].
Carlsson, H ;
Nilsson, U ;
Becker, G ;
Ostman, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (10) :2931-2936
[5]   Organophosphate flame retardants and plasticizers in indoor air [J].
Hartmann, PC ;
Bürgi, D ;
Giger, W .
CHEMOSPHERE, 2004, 57 (08) :781-787
[6]   Screening of organophosphorus compounds and their distribution in various indoor environments [J].
Marklund, A ;
Andersson, B ;
Haglund, P .
CHEMOSPHERE, 2003, 53 (09) :1137-1146
[7]  
Nagorka R, 2003, GEFAHRST REINHALT L, V63, P79
[8]   Analysis of organic esters of plasticizer in indoor air by GC-MS and GC-FPD [J].
Otake, T ;
Yoshinaga, J ;
Yanagisawa, Y .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) :3099-3102
[9]   Indoor air sampling of organophosphate triesters using solid phase extraction (SPE) adsorbents [J].
Staaf, T ;
Östman, C .
JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (04) :344-348
[10]  
WHO, 2000, ENV HLTH CRIT, V218