Comparative recovery of microorganisms from BacT/ALERT plastic and glass FA and FN blood culture bottles

被引:4
|
作者
Riley, JA [1 ]
Heiter, BJ [1 ]
Bourbeau, PP [1 ]
机构
[1] Geisinger Med Ctr, Div Lab Med, Danville, PA 17822 USA
关键词
D O I
10.1128/JCM.43.7.3244-3246.2005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
bioMerieux, Inc., has recently introduced plastic bottles to replace glass bottles for use in the BacT/ALERT blood culture system. We compared the performance of the plastic to the glass bottles in a large clinical evaluation. Two blood cultures were collected from each patient, one using glass FA (aerobic) and FN (anaerobic) bottles and one using plastic FA and FN bottles. Of the 4,040 sets of four bottles collected, 3,110 contained the recommended 8 to 12 ml of blood, yielding 524 microorganisms with 359 judged to be clinically significant. Of the 359 significant organisms, 255 were recovered in either one or two bottles from both pairs of bottles in a set while 56 organisms were recovered only from the glass bottles and 48 were recovered only from the plastic bottles (P, not significant [NS]). Of the 286 significant organisms recovered only in the FA bottles (glass and plastic), 180 were recovered in both bottles, 57 in the plastic bottles only, and 49 in the glass bottles only (P, NS). Of the 303 significant organisms recovered in the FN bottles only (glass and plastic), 212 were recovered in both bottles, 46 in the plastic bottles only, and 45 in the glass bottles only (P, NS). For individual organisms, the only significant difference in recovery was obtained for Escherichia coli, with more isolates recovered in the FN plastic than in the FN glass bottles (P = 0.02). These data suggest that recovery of microorganisms with plastic FA/FN bottles is at least equal to that with glass FA/FN bottles while offering greater safety for users.
引用
收藏
页码:3244 / 3246
页数:3
相关论文
共 50 条
  • [41] CONTROLLED EVALUATION OF BACT ALERT STANDARD ANAEROBIC AND FAN ANAEROBIC BLOOD CULTURE BOTTLES FOR THE DETECTION OF BACTEREMIA AND FUNGEMIA
    WILSON, ML
    WEINSTEIN, MP
    MIRRETT, S
    REIMER, LG
    FELDMAN, RJ
    CHUARD, CR
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (09) : 2265 - 2270
  • [42] Evaluation of BacT/ALERT plastic culture bottles for use in testing pooled whole blood derived leukocyte reduced PRP platelets with a single contaminated unit
    Brecher, ME
    Hay, SN
    Rose, AD
    Rothenberg, SJ
    TRANSFUSION, 2005, 45 (03) : 25A - 25A
  • [43] The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS
    Almuhayawi, Mohammed
    Altun, Osman
    Abdulmajeed, Adam Dilshad
    Ullberg, Mans
    Ozenci, Volkan
    PLoS One, 2015, 10 (11):
  • [44] Validation of BacT/ALERT plastic culture bottles for use in testing of whole-blood-derived leukoreduced platelet rich-plasma-derived platelets
    Brecher, ME
    Hay, SN
    Rothenberg, SJ
    TRANSFUSION, 2004, 44 (08) : 1174 - 1178
  • [45] Comparative evaluation of Vitek 2 identification and susceptibility testing of Gram-negative rods directly and isolated from BacT/ALERT-positive blood culture bottles
    M. J. Munoz-Dávila
    G. Yagüe
    M. Albert
    T. García-Lucas
    European Journal of Clinical Microbiology & Infectious Diseases, 2012, 31 : 663 - 669
  • [46] Comparative evaluation of Vitek 2 identification and susceptibility testing of Gram-negative rods directly and isolated from BacT/ALERT-positive blood culture bottles
    Munoz-Davila, M. J.
    Yaguee, G.
    Albert, M.
    Garcia-Lucas, T.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2012, 31 (05) : 663 - 669
  • [47] Clinical comparison of nonvented aerobic BacT/Alert blood culture bottle and standard aerobic bottle for detection of microorganisms in blood
    Snyder, JW
    Benzing, KS
    Munier, GK
    Bostic, GD
    Bozigar, PS
    Hanna, R
    Zervos, MJ
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (10) : 3864 - 3866
  • [48] Comparative evaluation of BACTEC FX, BacT/ALERT 3D, and BacT/ALERT VIRTUO-automated blood culture systems using simulated blood cultures
    Li, Zhengkang
    Liu, Suling
    Chen, Huimin
    Zhang, Xinqiang
    Ling, Yong
    Zhang, Ni
    Hou, Tieying
    ACTA CLINICA BELGICA, 2022, 77 (01) : 71 - 78
  • [49] Effect of delayed incubation of blood culture bottles in detecting bacterial growth with the Bact/Alert 3D system
    Ceballos, E
    Martínez-Martínez, L
    de Cueto, M
    Clavijo, MJ
    Pascual, A
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2001, 19 (07): : 350 - 351
  • [50] CONTROLLED EVALUATION OF 5-MILLILITERS VERSUS 10-MILLILITERS OF BLOOD CULTURED IN AEROBIC BACT/ALERT BLOOD CULTURE BOTTLES
    WEINSTEIN, MP
    MIRRETT, S
    WILSON, ML
    REIMER, LG
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (09) : 2103 - 2106