摘要
Membrane based indirect contact liquid desiccant dehumidification technology subsides the serious concern of liquid desiccant droplet carryover observed in conventional direct contact liquid desiccant systems. In the membrane contactor the air and liquid desiccant streams flow in alternate channels in cross-flow arrangement, separated by micro-porous semi-permeable hydrophobic membranes. Only water vapor can pass through the membranes but liquid desiccant cannot permeate. A two-dimensional steady-state mathematical model for semipermeable membrane based indirect contactors as dehumidifiers for liquid desiccant dehumidification applications has been developed. The model can predict the air and desiccant parameters inside the dehumidifier and the outlet parameters for a given input parameters. Five different membrane contactors have been fabricated and series of experiments have been conducted to validate the mathematical model. Aqueous solution of lithium chloride has been used as desiccant. The maximum deviations between experimental and predicted values are within +/- 10% for outlet specific humidity and outlet enthalpy of air, +/- 15% deviation in dehumidification effectiveness and +/- 20% deviation in enthalpy effectiveness. The distributions of major parameters viz, temperature, humidity, concentration, etc., within the contactor have been presented. Parametric analysis has been carried out to study the effects of membrane characteristics, contactor design, fluid flow rates, ambient conditions and desiccant concentration on the performance of the contactors. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 34 条
[1]   Annual evaluation of energy, environmental and economic performances of a membrane liquid desiccant air conditioning system with/without ERV [J].
Abdel-Salam, Ahmed H. ;
Simonson, Carey J. .
APPLIED ENERGY, 2014, 116 :134-148
[2]   Performance analysis of a membrane liquid desiccant air-conditioning system [J].
Abdel-Salam, Ahmed H. ;
Ge, Gaoming ;
Simonson, Carey J. .
ENERGY AND BUILDINGS, 2013, 62 :559-569
[3]   Expected energy and economic benefits, and environmental impacts for liquid-to-air membrane energy exchangers (LAMEEs) in HVAC systems: A review [J].
Abdel-Salam, Mohamed R. H. ;
Fauchoux, Melanie ;
Ge, Gaoming ;
Besant, Robert W. ;
Simonson, Carey J. .
APPLIED ENERGY, 2014, 127 :202-218
[4]   Performance analysis of a liquid desiccant and membrane contactor hybrid air-conditioning system [J].
Bergero, Stefano ;
Chiari, Anna .
ENERGY AND BUILDINGS, 2010, 42 (11) :1976-1986
[5]   Properties of aqueous solutions of lithium and calcium chlorides: formulations for use in air conditioning equipment design [J].
Conde, MR .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2004, 43 (04) :367-382
[6]  
Conde MR, 2008, OPEN ABSORPTION SYST
[7]   Experimental performance of indirect air-liquid membrane contactors for liquid desiccant cooling systems [J].
Das, Rajat Subhra ;
Jain, Sanjeev .
ENERGY, 2013, 57 :319-325
[8]  
Dieckmann J, 2011, ASHRAE J
[9]   Research and applications of liquid-to-air membrane energy exchangers in building HVAC systems at University of Saskatchewan: A review [J].
Ge, Gaoming ;
Abdel-Salam, Mohamed R. H. ;
Besant, Robert W. ;
Simonson, Carey J. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 26 :464-479
[10]  
Hewitt G. F., 2008, HEAT EXCHANGER DES 2