Rebar corrosion in chloride environment

被引:65
作者
Pradhan, Bulu [1 ]
Bhattacharjee, B. [2 ]
机构
[1] Indian Inst Technol Guwahati, Dept Civil Engn, Gauhati 781039, India
[2] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
关键词
Corrosion; Chloride; Reinforcement; Concrete; REINFORCED-CONCRETE; FLY-ASH; CONTAMINATED CONCRETE; CEMENT TYPE; STEEL; THRESHOLD; MORTAR; BARS; POLARIZATION; PERFORMANCE;
D O I
10.1016/j.conbuildmat.2010.11.099
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Chloride induced reinforcement corrosion in concrete is a serious durability problem. Different sources of chloride, i.e. chloride introduced at the fresh stage of concrete (i.e. internal chloride) and chloride entered during the hardened state (i.e. external chloride) may affect the performance of concrete in different ways. For the performance evaluation of reinforced concrete in chloride environment (i.e. both internal and external chloride), there is a need for performing different electrochemical tests to obtain various corrosion parameters that will specify the possibility and the magnitude of corrosion in concrete. In the present study, the results of an experimental investigation that includes different corrosion tests namely potential measurement, corrosion rate measurement and potentiodynamic polarization test have been presented and analyzed to evaluate the performance of concrete both in internal chloride and external chloride exposure conditions. In addition an attempt is made to correlate the corrosion parameters obtained from internal and external chloride exposure conditions. From the results it was observed that, dropped half-cell potential value obtained from external chloride exposure mostly lie in the active zone obtained from internal chloride exposure. In addition it was observed that there was significant difference in corrosion current values obtained from both internal and external chloride exposure conditions. Further on the basis of overall ranking obtained from the results of critical parameters from different exposure conditions, the performance of different cement-steel combinations against chloride induced rebar corrosion has been evaluated. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2565 / 2575
页数:11
相关论文
共 29 条
[1]   Chloride threshold values to depassivate reinforcing bars embedded in a standardized OPC mortar [J].
Alonso, C ;
Andrade, C ;
Castellote, M ;
Castro, P .
CEMENT AND CONCRETE RESEARCH, 2000, 30 (07) :1047-1055
[2]   Corrosion rate evolution in concrete structures exposed to the atmosphere [J].
Andrade, C ;
Alonso, C ;
Sarría, J .
CEMENT & CONCRETE COMPOSITES, 2002, 24 (01) :55-64
[3]  
[Anonymous], 2009, ANN BOOK ASTM STAND
[4]  
[Anonymous], 1999, C87691 ASTM
[5]  
[Anonymous], 60CSC RILEM
[6]  
[Anonymous], 2005, G10999A ASTM
[7]  
*ASTM, 2004, G594 ASTM
[8]   Monitoring electrical resistance of concretes containing alternative cementitious materials to assess their resistance to chloride penetration [J].
Basheer, PAM ;
Gilleece, PRV ;
Long, AE ;
Mc Carter, WJ .
CEMENT & CONCRETE COMPOSITES, 2002, 24 (05) :437-449
[9]  
Bertolini L., 2013, Corrosion of Steel in Concrete: Prevention,Diagnosis, Repair
[10]   Accelerated simultaneous determination of the chloride depassivation threshold and of the non-stationary diffusion coefficient values [J].
Castellote, M ;
Andrade, C ;
Alonso, C .
CORROSION SCIENCE, 2002, 44 (11) :2409-2424