The effect of hydroxyapatite nanocrystals on early bone formation surrounding dental implants

被引:32
|
作者
Svanborg, L. M. [1 ,2 ]
Hoffman, M. [2 ]
Andersson, M. [3 ]
Currie, F. [4 ]
Kjellin, P. [4 ]
Wennerberg, A. [1 ,2 ]
机构
[1] Malmo Univ, Dept Prosthodont, Fac Odontol, S-20506 Malmo, Sweden
[2] Gothenburg Univ, Dept Biomat Handicap Res, Inst Clin Sci, S-41124 Gothenburg, Sweden
[3] Chalmers Univ Technol, Dept Chem & Biol Engn, Gothenburg, Sweden
[4] Promimic AB, Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
nanostructures; surface topography; hydroxyapatite coat; dental implants; in vivo study; TITANIUM IMPLANTS; CALCIUM-PHOSPHATE; ENHANCED FUNCTIONS; REMOVAL TORQUE; ORAL IMPLANTS; SURFACE; OSTEOBLASTS; DEPOSITION; COATINGS; ADHESION;
D O I
10.1016/j.ijom.2010.10.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The knowledge of how nanostructures might affect early bone healing and osseointegration is limited. The aim of this study was to investigate if nanometer thick coatings of hydroxyapatite nanocrystals applied on a moderately rough surface might enhance early bone healing on screw-shaped dental implants and to evaluate if the thickness of the coat influences healing. Sandblasted and acid etched titanium implants coated with two different thicknesses of hydroxyapatite (test implants) and sandblasted and acid etched titanium implants (control implants), were inserted in rabbit tibia. After a healing time of 2, 4 and 9 weeks, a removal torque analysis and a histological evaluation were performed. The results from the removal torque analysis showed a tendency for higher values for the double coated hydroxyapatite after 4 weeks and for both the coated surfaces after 9 weeks of healing. The histological evaluations indicated slightly more new bone formation with the coated implants compared with the control; the differences did not reach statistical significance. The present study could not support the importance of nanometer thick coatings of hydroxyapatite nanocrystals in early bone healing, at least not when applied on a blasted and etched surface and placed in a cortical bone.
引用
收藏
页码:308 / 315
页数:8
相关论文
共 50 条
  • [41] Is there a lower threshold value of bone density for early loading protocols of dental implants?
    Turkyilmaz, I.
    McGlumphy, Edwin A.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 775 - 781
  • [42] Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs
    Arcesio Delgado-Ruiz, Rafael
    Markovic, Aleksa
    Luis Calvo-Guirado, Jose
    Lazic, Zoran
    Piattelli, Adriano
    Boticelli, Daniele
    Eduardo Mate-Sanchez, Jose
    Negri, Bruno
    Piedad Ramirez-Fernandez, Maria
    Misic, Tijana
    VOJNOSANITETSKI PREGLED, 2014, 71 (05) : 451 - 461
  • [43] Effect of bone density on the damping behavior of dental implants: An in vitro method
    VanSchoiack, Lindsey R.
    Wu, Jean C.
    Sheets, Cherilyn G.
    Earthman, James C.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (08): : 1307 - 1311
  • [44] Effect of the Nature of the Particles Released from Bone Level Dental Implants: Physicochemical and Biological Characterization
    Vara, Juan Carlos
    Delgado, Juan
    Estrada-Martinez, Alejandro
    Perez-Pevida, Esteban
    Brizuela, Aritza
    Bosch, Begona
    Perez, Roman
    Gil, Javier
    COATINGS, 2022, 12 (02)
  • [45] The Effect of V-Thread and Square Thread Dental Implants on Bone
    AL-Sanea, Abdulrahman
    Mutlu, Ibrahim
    Kisioglu, Yasin
    Mohamed, Eltahir
    JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2023, 60 : 83 - 96
  • [46] The burden of diabetes on the soft tissue seal surrounding the dental implants
    Zhang, Zhanwei
    Ji, Chonghao
    Wang, Daobin
    Wang, Maoshan
    Song, Dawei
    Xu, Xin
    Zhang, Dongjiao
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [47] Comparative bone tissue integration of nanostructured and microroughened dental implants
    Salou, Laetitia
    Hoornaert, Alain
    Stanovici, Julien
    Briand, Sylvain
    Louarn, Guy
    Layrolle, Pierre
    NANOMEDICINE, 2015, 10 (05) : 741 - 751
  • [48] Bone level around dental implants adjacent to teeth and implants
    Jairo Gomez-Guzman, John
    Marcela Arias-Holguin, Yohana
    Isabel Perez, Maria
    Augusto Restrepo-Restrepo, Felipe
    Rodriguez-Medina, Carolina
    Enrique Botero, Javier
    UNICIENCIA, 2022, 36 (01)
  • [49] Early healing of implants placed into fresh extraction sockets: an experimental study in the beagle dog. De novo bone formation
    Vignoletti, Fabio
    Johansson, Carina
    Albrektsson, Tomas
    De Sanctis, Massimo
    San Roman, Fidel
    Sanz, Mariano
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2009, 36 (03) : 265 - 277
  • [50] Bone autografts & allografts placed simultaneously with dental implants in rabbits
    Ribeiro, Marna
    Fraguas, Erica Hohlenwerger
    Brito, Keila Ilse Cangussu
    Kim, Yeon Jung
    Pallos, Debora
    Sendyk, Wilson Roberto
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (01) : 142 - 147