Determination of polydimethylsiloxane-seawater distribution coefficients for polychlorinated biphenyls and chlorinated pesticides by solid-phase microextraction and gas chromatography-mass spectrometry

被引:38
作者
Zeng, EY
Tsukada, D
Noblet, JA
Peng, H
机构
[1] Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangzhou 510640, Peoples R China
[2] So Calif Coastal Water Res Project, Westminster, CA 92683 USA
[3] Calif State Univ San Bernardino, Dept Chem, San Bernardino, CA 92407 USA
关键词
solid-phase microextraction; partition coefficient; hydrophobic organic compound; calibration;
D O I
10.1016/j.chroma.2005.01.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Applications of solid-phase microextraction (SPME) in the measurement of very hydrophobic organic compounds (VHOCs) are limited, partly due to the difficulty of calibrating SPME fibers for VHOCs. This study used a static SPME strategy with a large sample volume (I 6 L) and a five-point calibration procedure to determine the distribution coefficients for a large suite of polychlorinated biphenyls (PCBs) and chlorinated pesticides between a polydimethylsiloxane (PDMS) phase (100 mum thickness) coated on a glass fiber and seawater.. An extraction time of 12 days was deemed adequate for equilibrium calibration from kinetic experiments. Two groups of randomly selected fibers divided into three batches (up to nine fibers in each batch) were processed separately with two gas chromatography-mass spectrometry (GC-MS) systems. Matrix effects arising from losses of the analytes to glass container walls and stirring bars were corrected. Relative standard deviations within the same batch were generally smaller than those for the entire group. Furthermore, KfVf (K-f and V-f are the distribution coefficient of an analyte between the polymer-coated fiber and aqueous phase and the fiber volume, respectively) values determined with two GC-MS systems were statistically different. These results indicate the calibrated KfVf. values were less affected by the random selection of SPME fibers than by other experimental conditions, and therefore average KfVf values may be used for the same type of commercially available SPME fibers. The relative accuracy of our calibration method was similar to that of a previous study [P. Mayer, W.H.J. Vaes, J.L.M. Herinens, Anal. Chem. 72 (2000) 459] employing different coating thickness and calibration procedure. The present study also obtained a bell-shaped relationship between log K-f and log K-ow (octanol-water partition coefficient) for PCB congeners with the maximum log K-f corresponding to log K-ow similar to 6.5. This bell-shaped relationship was attributed mainly to steric effects arising from the interplay between the PDMS thickness and molecular sizes of the target analytes. (C) 2005 Elsevier B.V All rights reserved.
引用
收藏
页码:165 / 175
页数:11
相关论文
共 30 条
[1]   Solid phase microextraction for quantitative analysis in nonequilibrium situations [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1230-1236
[2]  
[Anonymous], 014201 US GEOL SURV
[3]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[4]  
CROSS N, 1994, SO CALIFORNIA COASTA, P75
[5]   DETERMINATION OF OCTANOL WATER PARTITION-COEFFICIENTS FOR HYDROPHOBIC ORGANIC-CHEMICALS WITH THE SLOW-STIRRING METHOD [J].
DEBRUIJN, J ;
BUSSER, F ;
SEINEN, W ;
HERMENS, J .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1989, 8 (06) :499-512
[6]   Determination of distribution coefficients of priority polycyclic aromatic hydrocarbons using solid-phase microextraction [J].
Doong, RA ;
Chang, SM .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3647-3652
[7]   OCTANOL WATER PARTITION-COEFFICIENTS OF POLYCHLORINATED BIPHENYL CONGENERS [J].
HAWKER, DW ;
CONNELL, DW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (04) :382-387
[8]   Negligible depletion solid-phase microextraction with radiolabeled analytes to study free concentrations and protein binding:: An example with [3H]Estradiol [J].
Heringa, MB ;
Pastor, D ;
Algra, J ;
Vaes, WHJ ;
Hermens, JLM .
ANALYTICAL CHEMISTRY, 2002, 74 (23) :5993-5997
[9]   Measurement of free concentrations using negligible depletion-solid phase microextraction (nd-SPME) [J].
Heringa, MB ;
Hermens, JLM .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (09) :575-587
[10]   Measured pore-water concentrations make equilibrium partitioning work - A data analysis [J].
Kraaij, R ;
Mayer, P ;
Busser, FJM ;
Bolscher, MV ;
Seinen, W ;
Tolls, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (02) :268-274