Red blood cell (RBC) volume can be independently determined in vivo in the sheep using ovine RBCs labeled at different densities of biotin

被引:13
作者
Mock, Donald M. [1 ]
Matthews, Nell I.
Zhu, Shan
Burmeister, Leon F.
Zimmerman, M. Bridget
Strauss, Ronald G.
Schmidt, Robert L.
Nalbant, Demet
Freise, Kevin J.
Veng-Pedersen, Peter
Widness, John A.
机构
[1] Univ Arkansas Med Sci Hosp, Dept Biochem & Mol Biol, Little Rock, AR 72205 USA
关键词
SURVIVAL; VALIDATION; BABOON; LAMBS;
D O I
10.1111/j.1537-2995.2010.02744.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To investigate the pathophysiology of anemia and responses to red blood cell (RBC) transfusions and erythropoietin, repeated measurement of the circulating red blood cell volume (RCV) would be useful. Ovine erythropoiesis is similar to human erythropoiesis. Accordingly, a method for measuring RCV using either human or sheep RBCs labeled at different biotin densities has been previously validated in vitro. Here preclinical studies validating this method for in vivo measurement of circulating RCV in sheep are reported. STUDY DESIGN AND METHODS: For each sheep, autologous RBCs were biotinylated were at four discrete densities (12, 24, 48, and 96 mu g biotinylation reagent/mL RBCs). The densities were mixed and infused intravenously. Blood was sampled five times over 1 hour beginning at 4 minutes. RCV values were determined based on dilution of each population of biotinylated RBCs and by the [14C]cyanate method. RESULTS: There was no difference among RCVs measured at all densities through 16 minutes; however, by 60 minutes, RBCs biotinylated at the highest density overestimated RCV by 7.6%. RCV values increased 41% over the hour, consistent with equilibration with a pool of RBCs sequestered in the spleen. RCV by the [14C]cyanate method paralleled results by the biotin method but averaged 8% greater. CONCLUSIONS: These studies provide evidence that all four densities of biotinylated RBCs can be used in sheep to simultaneously and independently determine RCV. We speculate that the multidensity biotinylation method will be useful both for multiple simultaneous measurements and for repeated measurement of circulating RCV and blood volume in humans.
引用
收藏
页码:2553 / 2564
页数:12
相关论文
共 22 条
[1]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[2]  
BLUNT MH, 1975, HEMOGLOBINS SHEEP BL
[3]   BLOOD-VOLUME AND ITS MEASUREMENT IN THE CHRONICALLY CATHETERIZED SHEEP FETUS [J].
BRACE, RA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1983, 244 (04) :H487-H494
[4]  
BRACE RA, 1984, ANIMAL MODELS FETAL, P19
[5]  
HECKER JF, 1983, SHEEP EXPT ANIMAL
[6]   OXYGEN DELIVERY IN LAMBS - CARDIOVASCULAR AND HEMATOLOGIC DEVELOPMENT [J].
LISTER, G ;
WALTER, TK ;
VERSMOLD, HT ;
DALLMAN, PR ;
RUDOLPH, AM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (06) :H668-H675
[7]   Circulating red cell volume and red cell survival can be accurately determined in sheep using the [C-14]cyanate label [J].
Mock, DM ;
Lankford, GL ;
Burmeister, LF ;
Strauss, RG .
PEDIATRIC RESEARCH, 1997, 41 (06) :916-921
[8]   [C-14]cyanate labeling of sheep red cells: Covalent binding to hemoglobin continues in vivo for a day [J].
Mock, DM ;
Strauss, RG ;
Lankford, GL .
PEDIATRIC RESEARCH, 1997, 41 (03) :424-429
[9]   RBCs labeled at two biotin densities permit simultaneous and repeated measurements of circulating RBC volume [J].
Mock, DM ;
Lankford, GL ;
Widness, JA ;
Burmeister, LF ;
Kahn, D ;
Strauss, RG .
TRANSFUSION, 2004, 44 (03) :431-437
[10]   Measurement of circulating red cell volume using biotin-labeled red cells:: validation against 51Cr-labeled red cells [J].
Mock, DM ;
Lankford, GL ;
Widness, JA ;
Burmeister, LF ;
Kahn, D ;
Strauss, RG .
TRANSFUSION, 1999, 39 (02) :149-155