Mechanical properties of the everolimus-eluting bioresorbable vascular scaffold compared to the metallic everolimus-eluting stent

被引:13
|
作者
Dalos, Daniel [1 ]
Gangl, Clemens [1 ]
Roth, Christian [1 ]
Krenn, Lisa [1 ]
Scherzer, Sabine [1 ]
Vertesich, Markus [1 ]
Lang, Irene [1 ]
Maurer, Gerald [1 ]
Neunteufl, Thomas [2 ]
Berger, Rudolf [3 ]
Delle-Karth, Georg [4 ]
机构
[1] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Univ Hosp Krems, Div Cardiol, Dept Internal Med, Krems, Austria
[3] Barmherzige Bruder Eisenstadt, Div Cardiol, Dept Internal Med, Eisenstadt, Austria
[4] Krankenhaus Hietzing, Div Cardiol, Dept Internal Med, Vienna, Austria
来源
BMC CARDIOVASCULAR DISORDERS | 2016年 / 16卷
关键词
Bioresorbable Scaffold; Drug-Eluting Stent; Optical Coherence Tomography; OPTICAL COHERENCE TOMOGRAPHY; PERCUTANEOUS CORONARY INTERVENTION; ROUTINE CLINICAL-PRACTICE; THROMBOSIS; ABSORB; 2ND-GENERATION; OUTCOMES; MULTICENTER; STENOSIS; IMPLANTATION;
D O I
10.1186/s12872-016-0296-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Everolimus-eluting bioresorbable vascular scaffolds (BVS) represent an innovative treatment option for coronary artery disease. Clinical and angiographic results seem promising, however, data on its immediate procedural performance are still scarce. The aim of our study was to assess the mechanical properties of BVS by Optical Coherence Tomography (OCT) in clinical routine. Methods: Post-implantation OCT images of 40 BVS were retrospectively compared to those of 40 metallic everolimus-eluting stents (EES). Post-procedural device related morphological features were assessed. This included incidences of gross underexpansion and the stent eccentricity index (SEI, minimum/maximum diameter) as a measure for focal radial strength. Results: Patients receiving BVS were younger than those with EES (54.0 +/- 11.2 years versus 61.7 +/- 11.4 years, p = 0.012), the remaining baseline, vessel and lesion characteristics were comparable between groups. Lesion pre-dilatation was more frequently performed and inflation time was longer in the BVS than in the EES group (n = 34 versus n = 23, p = 0. 006 and 44.2 +/- 12.8 versus 25.6 +/- 8.4 seconds, p < 0.001, respectively). There were no significant differences in maximal inflation pressures and post-dilatation frequencies with non-compliant balloons between groups. Whereas gross device underexpansion was not significantly different, SEI was significantly lower in the BVS group (n = 12 (30 %) versus n = 14 (35 %), p = 0.812 and 0.69 +/- 0.08 versus 0.76 +/- 0.09, p < 0.001, respectively). There was no difference in major adverse cardiac event-rate at six months. Conclusion: Our data show that focal radial expansion was significantly reduced in BVS compared to EES in a clinical routine setting using no routine post-dilatation protocol. Whether these findings have impact on scaffold mid-term results as well as on clinical outcome has to be investigated in larger, randomized trials.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Midterm clinical outcomes with everolimus-eluting bioresorbable scaffolds versus everolimus-eluting metallic stents for percutaneous coronary interventions: a meta-analysis of randomised trials
    Cassese, Salvatore
    Byrne, Robert A.
    Juni, Peter
    Wykrzykowska, Joanna J.
    Puricel, Serban
    Ndrepepa, Gjin
    Schunkert, Heribert
    Fusaro, Massimiliano
    Cook, Stephane
    Kimura, Takeshi
    Henriques, Jose P. S.
    Serruys, Patrick W.
    Windecker, Stephan
    Kastrati, Adnan
    EUROINTERVENTION, 2018, 13 (13) : 1565 - 1573
  • [42] Xience V™ everolimus-eluting coronary stent
    Kukreja, Neville
    Onuma, Yoshinobu
    Serruys, Patrick W.
    EXPERT REVIEW OF MEDICAL DEVICES, 2009, 6 (03) : 219 - 229
  • [43] Mid-term clinical outcomes of ABSORB bioresorbable vascular scaffold versus everolimus-eluting stent for coronary bifurcation lesions
    Naganuma, Toru
    Kawamoto, Hiroyoshi
    Panoulas, Vasileios F.
    Latib, Azeem
    Tanaka, Akihito
    Mitomo, Satoru
    Ruparelia, Neil
    Jabbour, Richard J.
    Chieffo, Alaide
    Carlino, Mauro
    Montorfano, Matteo
    Colombo, Antonio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 246 : 26 - 31
  • [44] Coronary artery aneurysm formation within everolimus-eluting bioresorbable stent
    Serban, Razvan
    Scridon, Alina
    Dobreanu, Dan
    Elkaholut, Ayman
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (01) : E4 - E5
  • [45] The Real World Experience of the Everolimus-Eluting Coronary Stent System: Audit of Everolimus-Eluting Coronary Stents
    Aldous, Sally
    Smyth, David
    Blake, James
    McClean, Dougal
    Elliott, John
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2011, 24 (03) : 241 - 246
  • [46] Five-year angiographic, OCT and clinical outcomes of a randomized comparison of everolimus and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds
    Schukraft, Sara
    Arroyo, Diego
    Togni, Mario
    Goy, Jean-Jacques
    Wenaweser, Peter
    Stadelmann, Mathieu
    Baeriswyl, Gerard
    Muller, Olivier
    Stauffer, Jean-Christophe
    Puricel, Serban
    Cook, Stephane
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (03) : 523 - 532
  • [47] A Polymeric Bioresorbable Vascular Scaffold Versus an Everolimus-Eluting Stent in ST-Segment Elevation Myocardial Infarction
    Wernly, Bernhard
    Latib, Azeem
    Ielasi, Alfonso
    Jung, Christian
    JOURNAL OF INVASIVE CARDIOLOGY, 2019, 31 (09) : E271 - E272
  • [48] Long-term follow-up of therapeutic efficacy of everolimus-eluting bioresorbable vascular scaffold in comparison to everolimus-eluting stent in treatment of chronic total occlusion guided by intracoronary imaging
    Mohammad Abdallah Eltahlawi
    Abdel-Aziz Fouad Abdel-Aziz
    Abdel-Salam Sherif
    Khalid Abdel-Azeem Shokry
    Islam Elsayed Shehata
    The Egyptian Heart Journal, 72
  • [49] Serial Analysis of the Malapposed and Uncovered Struts of the New Generation of Everolimus-Eluting Bioresorbable Scaffold With Optical Coherence Tomography
    Gomez-Lara, Josep
    Radu, Maria
    Brugaletta, Salvatore
    Farooq, Vasim
    Diletti, Roberto
    Onuma, Yoshinobu
    Windecker, Stephan
    Thuesen, Leif
    McClean, Dougal
    Koolen, Jacques
    Whitbourn, Robert
    Dudek, Dariusz
    Smits, Pieter C.
    Regar, Evelyn
    Veldhof, Susan
    Rapoza, Richard
    Ormiston, John A.
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (09) : 992 - 1001
  • [50] Impact of different stent alloys on human vascular response to everolimus-eluting stent: An optical coherence tomography study: The OCTEVEREST
    Guagliumi, Giulio
    Capodanno, Davide
    Ikejima, Hideyuki
    Bezerra, Hiram G.
    Sirbu, Vasile
    Musumeci, Giuseppe
    Fiocca, Luigi
    Lortkipanidze, Nikoloz
    Vassileva, Angelina
    Tahara, Satoko
    Valsecchi, Orazio
    Costa, Marco A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 510 - 518