Measurement of impact force, simulation of fall and hip fracture

被引:28
作者
Gardner, TN [1 ]
Simpson, AHRW [1 ]
Booth, C [1 ]
Sprukkelhorst, P [1 ]
Evans, M [1 ]
Kenwright, J [1 ]
Evans, JG [1 ]
机构
[1] Nuffield Orthopaed Ctr, Oxford Orthopaed Engn Ctr, Oxford OX3 7LD, England
关键词
hip fracture; elderly; impact force; floor; neck of femur;
D O I
10.1016/S1350-4533(97)00041-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It has been shown that the incidence of hip fracture in the elderly may be influenced by the type of floor covering commonly used in homes for the elderly. This study describes the development of a method for modelling a fall during a hip fracture event, to examine the influence of different Boors on impact force. An impact transducer is dropped in free fall through a smooth plastic tube. The impactor nose of the transducer models the curvature of the greater trochanter, and a steel spring is used to simulate the compliance of the skeletal structure. A weight, which corresponds to one-sixteenth of average body mass, compresses the spring and applies force to the impactor nose on striking the Boor. The temporal variation in the force of impact with the floor is measured by the transducer to within 0.41 percent (SD = 0.63%, n = 10). Five common floor coverings were tested over a concrete floor slab (vinyl, loop carpet and pile carpet - both with and without underpad). ANOVA analysis showed that the differences between mean forces for each floor covering were highly significant (p > 0.001), with the thicker coverings producing 7 percent lower forces. The transducer may be used to examine the correlation between impact force and fracture incidence for a variety of different floors in homes for the elderly. (C) 1998 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 14 条
[1]  
BOOTH C, 1996, BR ORTH RES SOC P SE
[2]  
CAPE RDT, 1976, CAN MED ASSOC J, V115, P9
[3]  
GRAHAM BA, 1984, ORTHOPAEDIC NURSING, V6, P19
[4]   IMPACT NEAR THE HIP DOMINATES FRACTURE RISK IN ELDERLY NURSING-HOME RESIDENTS WHO FALL [J].
HAYES, WC ;
MYERS, ER ;
MORRIS, JN ;
GERHART, TN ;
YETT, HS ;
LIPSITZ, LA .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (03) :192-198
[5]   EFFECT OF EXTERNAL HIP PROTECTORS ON HIP-FRACTURES [J].
LAURITZEN, JB ;
PETERSEN, MM ;
LUND, B .
LANCET, 1993, 341 (8836) :11-13
[6]   READ MY HIPS - MEASURING TROCHANTERIC SOFT-TISSUE THICKNESS [J].
MAITLAND, LA ;
MYERS, ER ;
HIPP, JA ;
HAYES, WC ;
GREENSPAN, SL .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (02) :85-89
[7]   IMPACT ATTENUATION OF FLOOR COVERINGS IN SIMULATED FALLING ACCIDENTS [J].
MAKI, BE ;
FERNIE, GR .
APPLIED ERGONOMICS, 1990, 21 (02) :107-114
[8]  
ONEILL B, 1985, BIOMECHANICS TRAUMA
[9]  
Panero J., 1979, HUMAN DIMENSION INTE
[10]   THE MORTALITY AND SOCIAL PROGNOSIS OF HIP-FRACTURES - A PROSPECTIVE MULTIFACTORIAL STUDY [J].
PITTO, RP .
INTERNATIONAL ORTHOPAEDICS, 1994, 18 (02) :109-113