An adaptive squared-distance-weighted interpolation for volume reconstruction in 3D freehand ultrasound

被引:21
作者
Huang, Qing-Hua [1 ]
Zheng, Yong-Ping [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Hong Kong SAR, Hong Kong, Peoples R China
关键词
adaptive SDW interpolation; volume reconstruction; 3D ultrasound; speckle suppression;
D O I
10.1016/j.ultras.2006.06.040
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Volume reconstruction is a key procedure in 3D ultrasound imaging. An algorithm named as squared- distance- weighted ( SDW) interpolation has been earlier proposed to reduce the blurring effect in the 3D ultrasonic images caused by the conventional distance weighted ( DW) interpolation. However, the SDW parameter a, which controls the weight distribution, is a constant assigned by operators so that the interpolation effect is invariant for both sharp edges and speckle noises. In this paper, we introduced a new adaptive algorithm based on SDW interpolation for volume reconstruction of 3D freehand ultrasound. In the algorithm, the local statistics of pixels surrounding each voxel grid were used to adaptively adjust the parameter a in SDW. The voxel grids with a higher ratio of local variance and mean in their neighbourhoods would have a smaller a to make the image details sharper, while the voxel grids locating in regions with a lower ratio of local variance and mean would have a larger a to smooth image content in homogeneous regions, where speckle noise is usually observed and damages the image quality. By comparing the simulation results using the SDW and new adaptive algorithm, it was demonstrated that this new algorithm worked well in both edge preservation and speckle reduction. (c) 2006 Elsevier B. V. All rights reserved.
引用
收藏
页码:E73 / E77
页数:5
相关论文
共 12 条
[1]   Three-dimensional freehand ultrasound: Image reconstruction and volume analysis [J].
Barry, CD ;
Allott, CP ;
John, NW ;
Mellor, PM ;
Arundel, PA ;
Thomson, DS ;
Waterton, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1209-1224
[2]   Three-dimensional ultrasound imaging [J].
Fenster, A ;
Downey, DB ;
Cardinal, HN .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :R67-R99
[3]   Engineering a freehand 3D ultrasound system [J].
Gee, A ;
Prager, R ;
Treece, G ;
Berman, L .
PATTERN RECOGNITION LETTERS, 2003, 24 (4-5) :757-777
[4]   A new scanning approach for limb extremities using a water bag in freehand 3-D ultrasound [J].
Huang, QH ;
Zheng, YP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04) :575-583
[5]   Development of a portable 3D ultrasound imaging system for musculoskeletal tissues [J].
Huang, QH ;
Zheng, YP ;
Lu, MH ;
Chi, ZR .
ULTRASONICS, 2005, 43 (03) :153-163
[6]   AN ADAPTIVE WEIGHTED MEDIAN FILTER FOR SPECKLE SUPPRESSION IN MEDICAL ULTRASONIC IMAGES [J].
LOUPAS, T ;
MCDICKEN, WN ;
ALLAN, PL .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1989, 36 (01) :129-135
[7]   Reconstruction and visualization of irregularly sampled three- and four-dimensional ultrasound data for cerebrovascular applications [J].
Meairs, S ;
Beyer, J ;
Hennerici, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (02) :263-272
[8]   Three-dimensional ultrasound imaging [J].
Nelson, TR ;
Pretorius, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) :1243-1270
[9]  
RHOLING RN, 1999, MED IMAGE ANAL, V3, P339
[10]   A theoretical framework to three-dimensional ultrasound reconstruction from irregularly sampled data [J].
San José-Estépar, R ;
Martín-Fernández, M ;
Caballero-Martínez, PP ;
Alberola-López, C ;
Ruiz-Alzola, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (02) :255-269