Electrical system for measurement of breakdown voltage of vacuum and gas-filled tubes using a dynamic method

被引:16
|
作者
Pejovic, MM [1 ]
Milosavljevic, CS [1 ]
Pejovic, MM [1 ]
机构
[1] Univ Nis, Fac Elect Engn, YU-18001 Nish, Serbia, Serbia
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2003年 / 74卷 / 06期
关键词
D O I
10.1063/1.1571972
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article describes an electrical system aimed at measuring and data acquisition of breakdown voltages of vacuum and gas-filled tubes. The measurements were performed using a nitrogen-filled tube at 4 mbar pressure. Based on the measured breakdown voltage data as a function of the applied voltage increase rate, a static breakdown voltage is estimated for the applied voltage gradient ranging from 0.1 to 1 V s(-1) and from 1 to 10 V s(-1). The histograms of breakdown voltages versus applied voltage increase rates from 0.1 and 0.5 V s(-1) are approximated by the probability density functions using a fitting procedure. (C) 2003 American Institute of Physics.
引用
收藏
页码:3127 / 3129
页数:3
相关论文
共 50 条
  • [1] METHOD FOR DETERMINING THE BREAKDOWN VOLTAGE IN GAS-FILLED TUBES
    PEJOVIC, MM
    FILIPOVIC, RD
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1989, 67 (02) : 251 - 256
  • [2] The estimation of static breakdown voltage for gas-filled tubes at low pressures using dynamic method
    Pejovic, MM
    Milosavljevic, CS
    Pejovic, MM
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2003, 31 (04) : 776 - 781
  • [3] Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices
    Pejovic, Milic M.
    Denic, Dragan B.
    Pejovic, Momcilo M.
    Nesic, Nikola T.
    Vasovic, Nikola
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [4] WAVE BREAKDOWN IN LONG GAS-FILLED TUBES WITH PREIONIZATION
    SLAVIN, BB
    SOPIN, PI
    HIGH TEMPERATURE, 1990, 28 (02) : 172 - 179
  • [5] A NEW ELECTRICAL BREAKDOWN PHENOMENON IN GAS-FILLED INSULATING BULBS
    FRIEDMANN, D
    CURZON, FL
    YOUNG, J
    APPLIED PHYSICS LETTERS, 1981, 38 (06) : 414 - 415
  • [6] Digital system for vacuum and gas-filled devices testing
    Pejovic, MM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (01):
  • [7] Investigations of breakdown voltage and time delay of gas-filled surge arresters
    Pejovic, Milic M.
    Pejovic, Momcilo M.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (20) : 4417 - 4422
  • [8] ELECTRICAL BREAKDOWN TIME DELAY IN COMMERCIAL GAS-FILLED SURGE ARRESTERS
    Pejovic, Milic
    Dekic, Sasa
    Jovanovic, Bojan
    Fetahovic, Irfan
    Osmokrovic, Predrag
    2015 IEEE PULSED POWER CONFERENCE (PPC), 2015,
  • [9] STABILITY OF BREAKDOWN VOLTAGE OF GAS-FILLED DISCHARGERS, USED IN OPERATION OF PULSE VOLTAGE GENERATORS
    ZOLOTAREV, EI
    MUKHIN, VD
    POLYANSKII, LE
    TRAPEZNIKOV, VN
    ZHURNAL TEKHNICHESKOI FIZIKI, 1976, 46 (03): : 595 - 600
  • [10] METHOD FOR CONTROLLING DEUTERIUM PRESSURE IN GAS-FILLED NEUTRON TUBES
    GEL, EP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (05): : 1117 - &