Determination of optical probe interrogation field of near-infrared reflectance: phantom and Monte Carlo study

被引:2
作者
Bahadur, Ali N.
Giller, Cole A.
Kashyap, Dheerendra
Liu, Hanli
机构
[1] Univ Texas, Hlth Sci Ctr, Childrens Canc Res Inst, San Antonio, TX 78229 USA
[2] Baylor Univ, Med Ctr, Baylor Radiosurg Ctr, Dallas, TX 75246 USA
[3] Univ Texas, Dept Bioengn, Arlington, TX 76019 USA
关键词
D O I
10.1364/AO.46.005552
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An optical probe used to localize human brain tissues in vivo has been reported previously. It was able to sense the underlying tissue structure with an optical interrogation field, termed as "look ahead distance" (LAD). A new side-firing probe has been designed with its optical window along its side. We have defined the optical interrogation field of the new side probe as "look aside distance" (IASD). The purpose of this study is to understand the dependence of the LAD and LASD on the optical properties of tissue, the light source intensity, and the integration time of the detector, using experimental. and computational methods. The results show that a decrease in light intensity does decrease the LAD and LASD and that an increase in integration time of detection may not necessarily improve the depths of LAD and LASD. Furthermore, Monte Carlo simulation results suggest that the LAD/LASD decreases with an increase in reduced scattering coefficient to a point, after which the LAD/LASD remains constant. We expect that an optical interrogation field of a tip or side probe is approximately 1-2 mm in white matter and 2-3.5 mm in gray matter. These conclusions will help us optimally manipulate the parameter settings during surgery and determine the spatial resolution of the probe. (C) 2007 Optical Society of America.
引用
收藏
页码:5552 / 5561
页数:10
相关论文
共 28 条
[21]   Quantitative optical spectroscopy for tissue diagnosis [J].
RichardsKortum, R ;
SevickMuraca, E .
ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1996, 47 :555-606
[22]   MIE AND RAYLEIGH MODELING OF VISIBLE-LIGHT SCATTERING IN NEONATAL SKIN [J].
SAIDI, IS ;
JACQUES, SL ;
TITTEL, FK .
APPLIED OPTICS, 1995, 34 (31) :7410-7418
[23]  
UTZINGER U, 1999, ENCY SPECTROSCOPY SP
[24]  
VANDERZEE P, 1993, P SOC PHOTO-OPT INS, V1888, P454, DOI 10.1117/12.154665
[25]   Variation in output power of laser prostatectomy fibers: A need for power measurements [J].
vanSwol, CFP ;
Slaa, ET ;
Verdaasdonk, RM ;
delaRosette, JJMCH ;
Boon, TA ;
Kabalin, JN .
UROLOGY, 1996, 47 (05) :672-678
[26]  
WANG, 1997, COMPUT METH PROG BIO, V54, P142
[27]   MCML - MONTE-CARLO MODELING OF LIGHT TRANSPORT IN MULTILAYERED TISSUES [J].
WANG, LH ;
JACQUES, SL ;
ZHENG, LQ .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1995, 47 (02) :131-146
[28]   Statistical properties of the penetration of photons into a semi-infinite turbid medium: a random-walk analysis [J].
Weiss, GH .
APPLIED OPTICS, 1998, 37 (16) :3558-3563