Spinal loads during position changes

被引:25
作者
Rohlmann, A. [1 ]
Petersen, R. [1 ]
Schwachmeyer, V. [1 ]
Graichen, F. [1 ]
Bergmann, G. [1 ]
机构
[1] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
关键词
Spine; Load measurement; Telemetry; Change of body position; Physiotherapy; VERTEBRAL BODY REPLACEMENT; INTRADISCAL PRESSURE; IMPLANT;
D O I
10.1016/j.clinbiomech.2012.04.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Recommendations exist how patients should change from one body position to another in order to keep the spinal loads low. However, until now it is not clear whether the loads are in fact lower if the patients follow these recommendations. The aim was to measure the loads while changing the body position. Methods: Telemeterized vertebral body replacements have been inserted into 5 patients who had a severe compression fracture of a lumbar vertebral body. The acting loads were measured during a changing of the body position while lying and when moving from lying to sitting, from sitting to standing and vice versa. Findings: When the lying patients changed their position according to the physiotherapist's recommendations, the resultant force was nearly as high as it was during relaxed standing. Otherwise, the force was nearly twice as high. Changing from a lateral lying position to sitting and vice versa caused forces of about 180% of those seen for standing when the recommendations were heeded. Without instructions, the loads were about 70% higher. Use of a trapeze bar mounted to the bed did not increase the loads. Rising from a chair with the arms hanging down laterally led to average resultant forces of 380% related to standing. Placing the hands on armrests reduced this value to 180%. Interpretation: High forces may act on the spine when changing from one body position to another. These loads can be minimized when following the physiotherapist's instructions and when supporting the upper body by the arms. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:754 / 758
页数:5
相关论文
共 50 条
  • [1] Spinal Loads during Cycling on an Ergometer
    Rohlmann, Antonius
    Zander, Thomas
    Graichen, Friedmar
    Schmidt, Hendrik
    Bergmann, Georg
    PLOS ONE, 2014, 9 (04):
  • [2] Lifting up and laying down a weight causes high spinal loads
    Rohlmann, Antonius
    Zander, Thomas
    Graichen, Friedmar
    Bergmann, Georg
    JOURNAL OF BIOMECHANICS, 2013, 46 (03) : 511 - 514
  • [3] Loads on a spinal implant measured in vivo during whole-body vibration
    Rohlmann, Antonius
    Hinz, Barbara
    Bluethner, Ralph
    Graichen, Friedmar
    Bergmann, Georg
    EUROPEAN SPINE JOURNAL, 2010, 19 (07) : 1129 - 1135
  • [4] Loads on a spinal implant measured in vivo during whole-body vibration
    Antonius Rohlmann
    Barbara Hinz
    Ralph Blüthner
    Friedmar Graichen
    Georg Bergmann
    European Spine Journal, 2010, 19 : 1129 - 1135
  • [5] How does the way a weight is carried affect spinal loads?
    Rohlmann, A.
    Zander, T.
    Graichen, F.
    Schmidt, H.
    Bergmann, G.
    ERGONOMICS, 2014, 57 (02) : 262 - 270
  • [6] Spinal Loads during Post-Operative Physiotherapeutic Exercises
    Rohlmann, Antonius
    Schwachmeyer, Verena
    Graichen, Friedmar
    Bergmann, Georg
    PLOS ONE, 2014, 9 (07):
  • [7] Correlation between back shape and spinal loads
    Srbinoska, H.
    Dreischarf, M.
    Consmueller, T.
    Bergmann, G.
    Rohlmann, A.
    JOURNAL OF BIOMECHANICS, 2013, 46 (11) : 1972 - 1975
  • [8] Loads on an internal spinal fixation device during walking
    Rohlmann, A
    Bergmann, G
    Graichen, F
    JOURNAL OF BIOMECHANICS, 1997, 30 (01) : 41 - 47
  • [9] Comparison of in vivo measured loads in knee, hip and spinal implants during level walking
    Damm, Philipp
    Kutzner, Ines
    Bergmann, Georg
    Rohlmann, Antonius
    Schmidt, Hendrik
    JOURNAL OF BIOMECHANICS, 2017, 51 : 128 - 132
  • [10] Loads on an internal spinal fixation device during physical therapy
    Rohlmann, A
    Graichen, F
    Bergmann, G
    PHYSICAL THERAPY, 2002, 82 (01): : 44 - 52