Effect of openings and shear bolt pattern in seismic retrofit of reinforced concrete slab-column connections

被引:8
作者
Bo, Wensheng [1 ]
Polak, Maria Anna [1 ]
机构
[1] Univ Waterloo, Dept Civil & Environm Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Flat reinforced concrete slab; Opening; Column; Seismic; Punching; Shear bolt; Ductility;
D O I
10.1016/j.engstruct.2011.05.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study addresses seismic retrofit of reinforced concrete flat slab-column connections against punching shear failure. The tested slabs are retrofitted using shear bolts. These bolts were developed for installation in existing slabs by drilling holes around columns or concentrated load application points and then tightening against the slab surfaces. Slabs with and without openings are investigated. The effect of the pattern of shear reinforcing elements around the column area, namely orthogonal and radial is also investigated. This paper describes tests on six flat slab-column specimens; three with two openings at the column and three without openings. Among each of the three specimens in a group, one has no shear reinforcement; one is retrofitted in the orthogonal pattern; and one in the radial pattern. The test results, comparisons of the behavior of the specimens, and comparisons with the current code formulas are presented and discussed. The results indicate that shear bolts increase lateral drift capacity and ductility of the slab-column connections. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3329 / 3340
页数:12
相关论文
共 9 条
[1]  
Adetifa B, 2005, ACI STRUCT J, V102, P268
[2]  
[Anonymous], 2005, 318 ACI COMM
[3]  
[Anonymous], 2001, 10451200107 DIN
[4]  
[Anonymous], 1992112004 EN
[5]  
BU W, 2008, THESIS U WATERLOO
[6]  
Bu WS, 2009, ACI STRUCT J, V106, P514
[7]  
CSA Technical Committee on Reinforced Concrete Design, 2004, A23 3 04 DES CONCR S
[8]  
El-Salakawy EF, 2003, ACI STRUCT J, V100, P297
[9]  
PAN A, 1989, ACI STRUCT J, V86, P250