Comparison of chemiluminescent immunoassay and ELISA for measles IgG and IgM

被引:40
作者
de Ory, Fernando [1 ,2 ]
Minguito, Teodora [1 ]
Balfagon, Pilar [1 ]
Sanz, Juan C. [2 ,3 ]
机构
[1] Inst Salud Carlos III, Lab Serol, Ctr Nacl Microbiol, Madrid 28220, Spain
[2] CIBER Epidemiol & Salud Publ CIBERESP, Barcelona, Spain
[3] Lab Salud Publ Comunidad Madrid, Madrid, Spain
关键词
Chemiluminescent immunoassay; measles; enzyme immunoassay; LABORATORY DIAGNOSIS; VIRUS; CAPTURE; ANTIBODIES; OUTBREAK; ASSAYS;
D O I
10.1111/apm.12413
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
In the context of measles elimination, the identification of recent infections is important for clinical laboratories. Serological diagnosis is achieved by detecting specific IgG and IgM. Recently an automated chemiluminescent immunoassay (CLIA) (Liaison, DiaSorin, Italy) has been used to quantify the measles antibody. The aim of this study was to compare this assay with Enzygnost ELISA (Siemens, Germany), with final classification of discrepancies by indirect immunofluorescence (Euroimmun, Germany). For measles IgM, 204 sera were analyzed: 50IgM-positive, 104IgM-negative/IgG-positive, and 50 from other viral infections (B19V, rubella, mumps, CMV, and EBV). For the measles IgG assay, 162 samples were tested: 106 were positive and 56 were negative. For measles IgM, the sensitivity and specificity of CLIA against ELISA were 94% (95% CI: 83.2-98.6) and 100% (95% CI: 97.1-100), respectively; the corrected figures after the final classification of discrepancies were 100% (95% CI: 91.0-100) and 99.4% (95% CI: 96.1-100), respectively. In relation to IgG, the sensitivity and specificity of CLIA against ELISA were, respectively, 97.2% (95% CI: 91.7-99.4) and 92.9% (95% CI: 82.5-97.7), and 95.5% (95% CI: 89.5-98.3) and 100% (95% CI: 91.8-100) after the final classification. CLIA showed excellent sensitivity and specificity in detecting measles IgG and IgM antibodies, eliminating the need to aliquot specimens before carrying out the assay.
引用
收藏
页码:648 / 651
页数:4
相关论文
共 16 条
[1]   DETECTION OF IGM ANTIBODIES SPECIFIC FOR MEASLES-VIRUS BY CAPTURE AND INDIRECT ENZYME IMMUNOASSAYS [J].
ARISTA, S ;
FERRARO, D ;
CASCIO, A ;
VIZZI, E ;
DISTEFANO, R .
RESEARCH IN VIROLOGY, 1995, 146 (03) :225-232
[2]   Comparison of Three Automated Immunoassay Methods for the Determination of Epstein-Barr Virus-Specific Immunoglobulin M [J].
Berth, Mario ;
Bosmans, Eugene .
CLINICAL AND VACCINE IMMUNOLOGY, 2010, 17 (04) :559-563
[3]   Assessment of RNA amplification by multiplex RT-PCR and IgM detection by indirect and capture ELISAs for the diagnosis of measles and rubella [J].
Carlos Sanz, Juan ;
Mosquera, Mar ;
Ramos, Belen ;
Ramirez, Rosa ;
de Ory, Fernando ;
Emilio Echevarria, Juan .
APMIS, 2010, 118 (03) :203-209
[4]  
Centro Nacional de Epidemiologia. ISCIII, 2000, PLAN EL SAR ESP
[5]   Comparison of plaque reduction neutralisation test (PRNT) and measles virus-specific IgG ELISA for assessing immunogenicity of measles vaccination [J].
Cohen, B. J. ;
Doblas, D. ;
Andrews, N. .
VACCINE, 2008, 26 (50) :6392-6397
[6]   Evaluation of Four Commercial Systems for the Diagnosis of Epstein-Barr Virus Primary Infections [J].
de Ory, Fernando ;
Eulalia Guisasola, Maria ;
Carlos Sanz, Juan ;
Garcia-Bermejo, Isabel .
CLINICAL AND VACCINE IMMUNOLOGY, 2011, 18 (03) :444-448
[7]  
DesOry F, 2001, ENFERM INFEC MICR CL, V19, P409
[8]   Laboratory diagnosis, molecular characteristics, epidemiological and clinical features of an outbreak of measles in a low incidence population in Australia [J].
Jayamaha, Jude ;
Binns, Philippa L. ;
Fennell, Michael ;
Ferson, Mark J. ;
Newton, Peter ;
Tran, Thomas ;
Catton, Michael ;
Robertson, Peter ;
Rawlinson, William .
JOURNAL OF CLINICAL VIROLOGY, 2012, 54 (02) :168-173
[9]   Performance of the DiaSorin LIAISON® anti-HBs II for the detection of hepatitis B surface antibodies: Comparison with the Abbott Architect anti-HBs assay [J].
Kinn, Sophie ;
Akhavan, Sepideh ;
Agut, Henri ;
Thibault, Vincent .
JOURNAL OF CLINICAL VIROLOGY, 2011, 50 (04) :297-302
[10]   ADAPTATION OF A COMMERCIALLY AVAILABLE INDIRECT FLUORESCENT-ANTIBODY SLIDE TEST FOR MEASURING MEASLES-SPECIFIC IMMUNOGLOBULINS [J].
KLEIMAN, MB ;
BOCKHOLD, CA ;
ZIMMERMAN, SE ;
GRIFFIN, C ;
FRENCH, MLV ;
BARRETT, C .