An Inside Body Power and Bidirectional Data Transfer IC Module Pair

被引:0
作者
Lee, Edward K. F. [1 ]
机构
[1] Alfred Mann Fdn, Santa Clarita, CA 91355 USA
关键词
AC-DC converter; biomedical; data modulation and demodulation; power delivery; INTEGRATED-CIRCUIT; WIRELESS; DESIGN; MICROSYSTEM; DEVICES; LINKS;
D O I
10.1109/JSSC.2011.2157260
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An IC module pair utilizing only three wires was designed for biomedical implants with a master unit (MU) and a small, lightweight satellite unit (SU). Power was delivered from the MU to the SU using a three-phase signal and converted to dc in the SU IC module by a passive MOS ac-dc converter. Bidirectional data transfer between the two units was achieved by modulating the amplitudes (at periods that do not affect power delivery) and the positions of the rising and falling edges of the three-phase signal. A bidirectional data rate in the range of MB/s and an overall power efficiency of 90.2% for a 2.84-mW load were achieved in a 0.18-mu m CMOS process.
引用
收藏
页码:1820 / 1831
页数:12
相关论文
共 31 条
[1]  
[Anonymous], 2010, PROC IEEE INT SOLID, DOI [DOI 10.1109/ISSCC.2010.5434025, 10.1109/ISSCC.2010.5434025]
[2]   256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes [J].
Aziz, Joseph N. Y. ;
Abdelhalim, Karim ;
Shulyzki, Ruslana ;
Genov, Roman ;
Bardakjian, Berj L. ;
Derchansky, Miron ;
Serletis, Demitre ;
Carlen, Peter L. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2009, 44 (03) :995-1005
[3]   Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems [J].
Baker, Michael W. ;
Sarpeshkar, Rahul .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2007, 1 (01) :28-38
[4]  
Chae M S, 2008, IEEE INT SOL STAT CI, P146
[5]   An Integrated 256-Channel Epiretinal Prosthesis [J].
Chen, Kuanfu ;
Yang, Zhi ;
Hoang, Linh ;
Weiland, James ;
Humayun, Mark ;
Liu, Wentai .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2010, 45 (09) :1946-1956
[6]   A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring [J].
Cong, Peng ;
Chaimanonart, Nattapon ;
Ko, Wen H. ;
Young, Darrin J. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2009, 44 (12) :3631-3644
[7]   A Highly Flexible System for Microstimulation of the Visual Cortex: Design and Implementation [J].
Coulombe, Jonathan ;
Sawan, Mohamad ;
Gervais, Jean-Francois .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2007, 1 (04) :258-269
[8]  
Denison T., 2008, IEEE International Solid-State Circuits Conference Digest of Technical Papers, P162
[9]   A wide-band power-efficient inductive wireless link for implantable microelectronic devices using multiple-carriers [J].
Ghovanloo, Maysam ;
Atluri, Suresh .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2007, 54 (10) :2211-2221
[10]   A versatile integrated circuit for the acquisition of biopotentials [J].
Harrison, Reid R. .
PROCEEDINGS OF THE IEEE 2007 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2007, :115-122