The effects of bone and pore volume fraction on the mechanical properties of PMMA/bone biopsies extracted from augmented vertebrae

被引:13
作者
Kinzl, M. [1 ]
Boger, A. [2 ]
Zysset, P. K. [1 ]
Pahr, D. H. [1 ]
机构
[1] Vienna Univ Technol, Inst Lightweight Design & Struct Biomech, A-1040 Vienna, Austria
[2] Synthes GmbH, R&D Biomat, Oberdorf, Switzerland
关键词
Vertebroplasty; Cement; PMMA; Material properties; Pore volume; FINITE-ELEMENT MODELS; MATRIX; PMMA;
D O I
10.1016/j.jbiomech.2011.07.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Vertebroplasty forms a porous PMMA/bone composite which was shown to be weaker and less stiff than pure PMMA. It is not known what determines the mechanical properties of such composites in detail. This study investigated the effects of bone volume fraction (BV/TV), cement porosity (PV/(TV-BV), PV ... pore volume) and cement stiffness. Nine human vertebral bodies were augmented with either standard or low-modulus PMMA cement and scanned with a HR-pQCT system before and after augmentation. Fourteen cylindrical PMMA/bone biopsies were extracted from the augmented region, scanned with a micro-CT system and tested in compression until failure. Micro-finite element (FE) models of the complete biopsies, of the trabecular bone alone as well as of the porous cement alone were generated from CT images to gain more insight into the role of bone and pores. PV/(TV-BV) and experimental moduli of standard/low-modulus cement (R(2)=0.91/0.98) as well as PV/(TV-BV) and yield stresses (R(2)=0.92/0.83) were highly correlated. No correlation between BV/TV (ranging from 0.057 to 0.138) and elastic moduli was observed (R(2) < 0.05). Interestingly, the micro-FE models of the porous cement alone reproduced the experimental elastic moduli of the standard/low-modulus cement biopsies (R(2)=0.75/0.76) more accurately than the models with bone (R(2)=0.58/0.31). In conclusion, the mechanical properties of the biopsies were mainly determined by the cement porosity and the cement material properties. The study showed that bone tissue inside the biopsies was mechanically "switched off" such that load was carried essentially by the porous PMMA. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2732 / 2736
页数:5
相关论文
共 16 条
[1]   A scalable multi-level preconditioner for matrix-free μ-finite element analysis of human bone structures [J].
Arbenz, Peter ;
van Lenthe, G. Harry ;
Mennel, Uche ;
Mueller, Ralph ;
Sala, Marzio .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2008, 73 (07) :927-947
[2]   Biomechanical impact of vertebroplasty - Postoperative biomechanics of vertebroplasty [J].
Baroud, G ;
Bohner, M .
JOINT BONE SPINE, 2006, 73 (02) :144-150
[3]  
Baroud G., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P133, DOI 10.1080/1025584031000095746
[4]   Performance of vertebral cancellous bone augmented with compliant PMMA under dynamic loads [J].
Boger, Andreas ;
Bohner, Marc ;
Heini, Paul ;
Schwieger, Karsten ;
Schneider, Erich .
ACTA BIOMATERIALIA, 2008, 4 (06) :1688-1693
[5]   NMP-Modified PMMA Bone Cement with Adapted Mechanical and Hardening Properties for the Use in Cancellous Bone Augmentation [J].
Boger, Andreas ;
Wheeler, Kurtis ;
Montali, Andrea ;
Gruskin, Elliot .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 90B (02) :760-766
[6]   The accuracy of digital image-based finite element models [J].
Guldberg, RE ;
Hollister, SJ ;
Charras, GT .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (02) :289-295
[7]  
KUHN KD, 2000, UP TO DATE COMPARISO, V1
[8]   Comparison of structure extraction methods for in vivo trabecular bone measurements [J].
Laib, A ;
Rüegsegger, P .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (02) :69-74
[9]   Ordinary least square regression, orthogonal regression, geometric mean regression and their applications in aerosol science [J].
Leng, Ling ;
Zhang, Tianyi ;
Kleinman, Lawrence ;
Zhu, Wei .
SCIDAC 2007: SCIENTIFIC DISCOVERY THROUGH ADVANCED COMPUTING, 2007, 78
[10]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268