Functional magnetic resonance neuroimaging data acquisition techniques

被引:17
作者
Duyn, JH
Yang, YH
Frank, JA
Mattay, VS
Hou, L
机构
关键词
D O I
10.1006/nimg.1996.0057
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional MRI studies of human brain require rapid data acquisition techniques, to map dynamic changes with sufficient anatomical coverage. In addition, task activation studies employing functional MRI require a high scan sensitivity, in order to discriminate the small, activation-related signal changes from background noise. An overview is given of current fast scan methods, which are sensitized to detect susceptibility changes related to task-induced changes in blood oxygenation. Sources of artifacts are discussed, as well as their effect on image quality. (C) 1996 Academic Press, Inc.
引用
收藏
页码:S76 / S83
页数:8
相关论文
共 39 条
[1]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[2]   SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T [J].
BANDETTINI, PA ;
WONG, EC ;
JESMANOWICZ, A ;
HINKS, RS ;
HYDE, JS .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :12-20
[3]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[4]   FUNCTIONAL NMR IMAGING USING FAST SPIN-ECHO AT 1.5 T [J].
CONSTABLE, RT ;
KENNAN, RP ;
PUCE, A ;
MCCARTHY, G ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :686-690
[5]   INFLOW VERSUS DEOXYHEMOGLOBIN EFFECTS IN BOLD FUNCTIONAL MRI USING GRADIENT ECHOES AT 1.5 T [J].
DUYN, JH ;
MOONEN, CTW ;
VANYPEREN, GH ;
DEBOER, RW ;
LUYTEN, PR .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :83-88
[6]   3-DIMENSIONAL FUNCTIONAL IMAGING OF HUMAN BRAIN USING ECHO-SHIFTED FLASH MRI [J].
DUYN, JH ;
MATTAY, VS ;
SEXTON, RH ;
SOBERING, GS ;
BARRIOS, FA ;
LIU, GY ;
FRANK, JA ;
WEINBERGER, DR ;
MOONEN, CTW .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :150-155
[7]  
DUYN JH, 1996, IN PRESS MAGN RESON
[8]   APPLICATION OF FOURIER TRANSFORM SPECTROSCOPY TO MAGNETIC RESONANCE [J].
ERNST, RR ;
ANDERSON, WA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (01) :93-+
[9]   DYNAMIC MR IMAGING OF HUMAN BRAIN OXYGENATION DURING REST AND PHOTIC-STIMULATION [J].
FRAHM, J ;
BRUHN, H ;
MERBOLDT, KD ;
HANICKE, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :501-505
[10]   NUCLEAR MAGNETIC-RESONANCE SIGNAL FROM FLOWING NUCLEI IN RAPID IMAGING USING GRADIENT ECHOES [J].
GAO, JH ;
HOLLAND, SK ;
GORE, JC .
MEDICAL PHYSICS, 1988, 15 (06) :809-814