Infrequent physician use of implantable cardioverter-defibrillators risks patient safety

被引:16
|
作者
Lyman, Stephen [1 ]
Sedrakyan, Art [2 ]
Do, Huong [1 ]
Razzano, Renee [2 ]
Mushlin, Alvin I. [2 ]
机构
[1] Hosp Special Surg Epidemiol & Biostat, New York, NY 10021 USA
[2] Weill Cornell Med Coll, Dept Publ Hlth, New York, NY USA
基金
美国医疗保健研究与质量局;
关键词
NONISCHEMIC CARDIOMYOPATHY; PACEMAKER-IMPLANTATION; PROCEDURE VOLUME; COMPLICATIONS; PREVENTION; MORTALITY; ASSOCIATION; OUTCOMES; REPAIR; COST;
D O I
10.1136/hrt.2011.226282
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. Objectives To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Design Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients New York state residents undergoing ICD implantation. Main outcome measures Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. Results This cohort (N = 38 992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) post-implantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-low-volume operators were more likely to die (RR 1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR = 4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. Conclusions These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.
引用
收藏
页码:1655 / 1660
页数:6
相关论文
共 50 条
  • [21] Implantable cardioverter-defibrillators: a long-term view
    Wilson, D.
    Shi, B.
    Harding, S.
    Lever, N.
    Larsen, P.
    INTERNAL MEDICINE JOURNAL, 2012, 42 (05) : 554 - 561
  • [22] Implantable Cardioverter-Defibrillators Have Stood the Test of Time!
    Al-Khatib, Sana M.
    Kusumoto, Fred M.
    CIRCULATION, 2019, 140 (19) : 1540 - 1542
  • [23] Physicians' knowledge and attitudes regarding implantable cardioverter-defibrillators
    Sherazi, Saadia
    Zareba, Wojciech
    Daubert, James P.
    McNitt, Scott
    Shah, Abrar H.
    Aktas, Mehmet K.
    Block, Robert C.
    CARDIOLOGY JOURNAL, 2010, 17 (03) : 267 - 273
  • [24] An unmet need for implantable cardioverter-defibrillators in New Zealand
    Burgess, Sonya N.
    Harding, Scott A.
    Melton, Iain C.
    Lever, Nigel A.
    Swain, Andrew H.
    Shi, Bijia
    Larsen, Peter D.
    EUROPACE, 2011, 13 (09): : 1299 - 1303
  • [25] Implantable cardioverter-defibrillators in France: practices and regional variability
    Lazarus, Arnaud
    Biondi, Nelly
    Thebaut, Jean-Francois
    Durand-Zaleski, Isabelle
    Chauvin, Michel
    EUROPACE, 2011, 13 (11): : 1568 - 1573
  • [26] Variation in Use of Dual-Chamber Implantable Cardioverter-Defibrillators Results From the National Cardiovascular Data Registry
    Matlock, Dan D.
    Peterson, Pamela N.
    Wang, Yongfei
    Curtis, Jeptha P.
    Reynolds, Matthew R.
    Varosy, Paul D.
    Masoudi, Frederick A.
    ARCHIVES OF INTERNAL MEDICINE, 2012, 172 (08) : 634 - 641
  • [27] Physicians' perceptions of shared decision-making for implantable cardioverter-defibrillators: Results of a physician survey
    Ali-Ahmed, Fatima
    Matlock, Daniel
    Zeitler, Emily P.
    Thomas, Kevin L.
    Haines, David E.
    Al-Khatib, Sana M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2420 - 2426
  • [28] Meta-analysis: Age and Effectiveness of Prophylactic Implantable Cardioverter-Defibrillators
    Santangeli, Pasquale
    Di Biase, Luigi
    Dello Russo, Antonio
    Casella, Michela
    Bartoletti, Stefano
    Santarelli, Pietro
    Pelargonio, Gemma
    Natale, Andrea
    ANNALS OF INTERNAL MEDICINE, 2010, 153 (09) : 592 - 599
  • [29] Implications of Frailty Among Men With Implantable Cardioverter-Defibrillators
    Adabag, Selcuk
    Picel, Katherine
    Vo, Tien N.
    Kealhofer, Jessica
    Anand, Vidhu
    Ensrud, Kristine E.
    CIRCULATION, 2018, 138
  • [30] Implantable Cardioverter-Defibrillators Among Older Survivors of Out-of-Hospital Cardiac Arrest
    Marcus, Mason
    Chan, Paul S.
    Chang, Anping
    Merritt, Robert K.
    Mcnally, Bryan
    Link, Mark S.
    Girotra, Saket
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (19):