The influence of bileaflet prosthetic aortic valve orientation on the blood flow patterns in the ascending aorta

被引:10
作者
Gulan, Utku [1 ]
Holzner, Markus [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Environm Engn, HIL, IfU, Wolfgang Pauli Str 15, CH-8093 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Mechanical prosthetic heart valve; 3D-PTV; Aorta; Turbulence; Vortex; Shear stress; ARCH;
D O I
10.1016/j.medengphy.2018.07.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigate three-dimensional pulsatile aortic flow in the ascending aorta with mechanical prosthetic aortic valve implanted at two different orientations under physiological flow conditions using an anatomically accurate aorta. We perform 3D Particle Tracking Velocimetry measurements to assess the phase averaged and fluctuating velocity patterns as well as the shear stresses. A St Jude Medical prosthetic heart valve is implanted in an anatomically accurate silicone model of an aorta obtained from high resolution magnetic resonance imaging of a healthy proband at two different orientations. Our results show that the mechanical prosthetic valve orientation has considerable impact on the local kinetic energy and shear stress distributions but minor effects on the spatially averaged kinetic energy (10%) and shear stresses (15%). We show that the valve orientation plays a distinct role in spatial distribution of wall shear stresses and vortical structures. We show that our results, which show good agreement with the in silico and in vitro studies in the literature, provide full 3D kinetic energy and shear stress information over the entire cardiac cycle for different bileaflet prosthetic valve orientations under physiological flow conditions. (C) 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 31 条
[1]  
Akutsu T., 2000, J ARTIF ORGANS, V3, P126
[2]  
Akutsu T, 2001, J ARTIF ORGANS, V4, P113
[3]  
Annerel S, 2014, ANN BIOMED ENG, V43, P1
[4]  
APEL J, 2001, J ARTIF ORGANS, V25, P341
[5]   The relationship between wall shear stress distributions and intimal thickening in the human abdominal aorta [J].
Bonert, Michael ;
Leask, Richard L. ;
Butany, Jagdish ;
Ethier, C. Ross ;
Myers, Jerry G. ;
Johnston, K. Wayne ;
Ojha, Matadial .
BIOMEDICAL ENGINEERING ONLINE, 2003, 2 (1)
[6]  
Borazjani I, 2010, J BIOMECHANICAL ENG, V132
[7]   ORIENTATION OF BILEAFLET MECHANICAL AORTIC VALVE PROSTHESES FOR OPTIMAL EVALUATION BY TRANSTHORACIC ECHOCARDIOGRAPHY [J].
Bouzas-Mosquera, Alberto ;
Alvarez-Garcia, Nemesio .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (02) :428-430
[8]   EFFECT OF PROSTHETIC MITRAL-VALVE GEOMETRY AND ORIENTATION ON FLOW DYNAMICS IN A MODEL HUMAN LEFT-VENTRICLE [J].
CHANDRAN, KB ;
SCHOEPHOERSTER, R ;
DELLSPERGER, KC .
JOURNAL OF BIOMECHANICS, 1989, 22 (01) :51-&
[9]   FLUID MECHANICS OF ARTIFICIAL HEART VALVES [J].
Dasi, Lakshmi P. ;
Simon, Helene A. ;
Sucosky, Philippe ;
Yoganathan, Ajit P. .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2009, 36 (02) :225-237
[10]   Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography [J].
de Heer, Linda M. ;
Budde, Ricardo P. J. ;
Mali, Willem P. Th. M. ;
de Vos, Alexander M. ;
van Herwerden, Lex A. ;
Kluin, Jolanda .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (08) :1195-1204