The Difference Between GUM and ISO/TC 15530-3 Method to Evaluate the Measurement Uncertainty of Flatness by a CMM

被引:18
作者
Strbac, B. [1 ]
Radlovacki, V. [2 ]
Spasic-Jokic, V. [3 ]
Delic, M. [2 ]
Hadzistevic, M. [1 ]
机构
[1] Univ Novi Sad, Dept Prod Engn, Fac Tech Sci, Trg Dositeja Obradovica 6, Novi Sad 21000, Serbia
[2] Univ Novi Sad, Dept Ind Engn & Management, Fac Tech Sci, Trg Dositeja Obradovica 6, Novi Sad 21000, Serbia
[3] Univ Novi Sad, Dept Power Elect & Telecommun Engn, Fac Tech Sci, Trg Dositeja Obradovica 6, Novi Sad 21000, Serbia
来源
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA | 2017年 / 32卷 / 04期
关键词
Measurement uncertainty; Flatness; Coordinate measuring machine (CMM); TASK-SPECIFIC UNCERTAINTY; ERROR EVALUATION; COORDINATE; MODEL; SELECTION;
D O I
10.1007/s12647-017-0227-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Uncertainty estimation in coordinate measuring machine (CMM) measurements is one of the highest priority tasks in modern industrial world due to its importance in the manufacturing metrology, especially if we take into account the fact that workpieces, according to a new generation of geometrical product specifications, can be accepted/rejected only on the basis of the total measurement results. Evaluation of measurement uncertainty of a CMM is a complex task, especially in the verification of errors of forms. Among several standard methods that can be used to estimate measurement uncertainty, we performed a comparison between two of these for the case of flatness measurement. Optical flat was used in order to exclude a number of essential factors in the case study. The results showed that the expanded measurement uncertainty assessed by GUM is greater than the value of the expanded measurement uncertainty obtained using the ISO 15530 method. However, both methodologies have shown that the maximum permissible error of a CMM has the greatest impact on uncertainty and also, that the total result evaluated by both approaches is close to the maximum permissible error of a CMM.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 28 条
[1]  
[Anonymous], 1036022009 ISO 2
[2]  
[Anonymous], 1425322011 ISOTS 2
[3]  
[Anonymous], 1425312013 ISO 1
[4]  
[Anonymous], 2008, 1553042008 ISOTS 4
[5]  
[Anonymous], 2012, 11012012E ISO
[6]  
[Anonymous], 1553032011 ISOTS M
[7]   Sampling uncertainty in coordinate measurement data analysis [J].
Choi, W ;
Kurfess, TR ;
Cagan, J .
PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1998, 22 (03) :153-163
[8]   Research on the uncertainties from different form error evaluation methods by CMM sampling [J].
Cui, Changcai ;
Fu, Shiwei ;
Huang, Fugui .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2009, 43 (1-2) :136-145
[9]   Determination of validation threshold for coordinate measuring methods using a metrological compatibility model [J].
Gromczak, Kamila ;
Gaska, Adam ;
Kowalski, Marek ;
Ostrowska, Ksenia ;
Sladek, Jerzy ;
Gruza, Maciej ;
Gaska, Piotr .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (01)
[10]   Validation model for coordinate measuring methods based on the concept of statistical consistency control [J].
Gromczak, Kamila ;
Gaska, Adam ;
Ostrowska, Ksenia ;
Sladek, Jerzy ;
Harmatys, Wiktor ;
Gaska, Piotr ;
Gruza, Maciej ;
Kowalski, Marek .
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2016, 45 :414-422