Selective label-free electrochemical impedance measurement of glycated haemoglobin on 3-aminophenylboronic acid-modified eggshell membranes

被引:11
作者
Boonyasit, Yuwadee [1 ]
Heiskanen, Arto [2 ]
Chailapakul, Orawan [3 ,4 ]
Laiwattanapaisal, Wanida [5 ]
机构
[1] Chulalongkorn Univ, Fac Allied Hlth Sci, Grad Program Clin Biochem & Mol Med, Bangkok 10330, Thailand
[2] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[3] Chulalongkorn Univ, Dept Chem, EOSRU, Fac Sci, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Ctr Excellence Petrochem & Mat Technol PETROMAT, Bangkok 10330, Thailand
[5] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Bangkok 10330, Thailand
关键词
Glycated haemoglobin (HbA1c); Diabetes mellitus; 3-aminophenyl boronic acid; Eggshell membrane; Membrane-based biosensor; Selective label-free electrochemical detection; IFCC REFERENCE METHOD; ALUMINA MEMBRANE; BIOSENSOR; HBA(1C); IMMOBILIZATION; BINDING; GLUCOSE; INTERFERENCE; FABRICATION; ELECTRODES;
D O I
10.1007/s00216-015-8680-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We propose a novel alternative approach to long-term glycaemic monitoring using eggshell membranes (ESMs) as a new immobilising platform for the selective label-free electrochemical sensing of glycated haemoglobin (HbA1c), a vital clinical index of the glycaemic status in diabetic individuals. Due to the unique features of a novel 3-aminophenylboronic acid-modified ESM, selective binding was obtained via cis-diol interactions. This newly developed device provides clinical applicability as an affinity membrane-based biosensor for the identification of HbA1c over a clinically relevant range (2.3 - 14 %) with a detection limit of 0.19 %. The proposed membrane-based biosensor also exhibited good reproducibility. When analysing normal and abnormal HbA1c levels, the within-run coefficients of variation were 1.68 and 1.83 %, respectively. The run-to-run coefficients of variation were 1.97 and 2.02 %, respectively. These results demonstrated that this method achieved the precise and selective measurement of HbA1c. Compared with a commercial HbA1c kit, the results demonstrated excellent agreement between the techniques (n = 15), demonstrating the clinical applicability of this sensor for monitoring glycaemic control. Thus, this low-cost sensing platform using the proposed membrane-based biosensor is ideal for point-of-care diagnostics.
引用
收藏
页码:5287 / 5297
页数:11
相关论文
共 56 条
[1]   Chemiluminescent acridinium-9-carboxamide boronic acid probes: Application to a homogenous glycated hemoglobin assay [J].
Adamczyk, M ;
Chen, YY ;
Johnson, DD ;
Mattingly, PG ;
Moore, JA ;
Pan, Y ;
Reddy, RE .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2006, 16 (05) :1324-1328
[2]  
Amer Diabet Assoc, 2011, DIABETES CARE, V34, pS11, DOI [10.2337/dc10-S062, 10.2337/dc14-S081, 10.2337/dc11-S011, 10.2337/dc13-S011, 10.2337/dc13-S067, 10.2337/dc12-s064, 10.2337/dc11-S062, 10.2337/dc10-S011, 10.2337/dc12-s011]
[3]  
Bard A.J., 2001, ELECTROCHEMICAL METH
[4]   Role of oxidative stress in diabetic complications - A new perspective on an old paradigm [J].
Baynes, JW ;
Thorpe, SR .
DIABETES, 1999, 48 (01) :1-9
[5]   Biochemistry and molecular cell biology of diabetic complications [J].
Brownlee, M .
NATURE, 2001, 414 (6865) :813-820
[6]  
Bry L, 2001, CLIN CHEM, V47, P153
[7]   Detection of Total and A1c-Glycosylated Hemoglobin in Human Whole Blood Using Sandwich Immunoassays on Polydimethylsiloxane-Based Antibody Microarrays [J].
Chen, Huang-Han ;
Wu, Chih-Hsing ;
Tsai, Mei-Ling ;
Huang, Yi-Jing ;
Chen, Shu-Hui .
ANALYTICAL CHEMISTRY, 2012, 84 (20) :8635-8641
[8]   Immobilization of beef liver catalase on eggshell membrane for fabrication of hydrogen peroxide biosensor [J].
Choi, MMF ;
Yiu, TP .
ENZYME AND MICROBIAL TECHNOLOGY, 2004, 34 (01) :41-47
[9]   An optical glucose biosensor with eggshell membrane as an enzyme immobilisation platform [J].
Choi, MMF ;
Pang, WSH ;
Xiao, D ;
Wu, XJ .
ANALYST, 2001, 126 (09) :1558-1563
[10]   Detection of glycated hemoglobin (HbA1c) based on impedance measurement with parallel electrodes integrated into a microfluidic device [J].
Chuang, Ya-Chun ;
Lan, Kung-Chieh ;
Hsieh, Ku-Meng ;
Jang, Ling-Sheng ;
Chen, Ming-Kun .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 :1222-1230