Study Design. Cadaveric biomechanical study. Objectives. To compare the biomechanical stability of two-level PLIF constructs with unilateral and bilateral pedicle screw fixations. Methods. Six cadaveric lumbar segments were evaluated to assess biomechanical stability in response to pure moment loads applied in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Each specimen was tested in six sequential configurations: (1) intact baseline; (2) facetectomy; (3) unilateral pedicle screws (UPS); (4) bilateral pedicle screws (BPS); (5) unilateral pedicle screws and cage (UPSC); and (6) bilateral pedicle screws and cage (BPSC). Results. Significant reductions in motion were observed when comparing all instrumented conditions to the intact and facetectomy stages of testing. No significant differences in motion between UPS, BPS, UPSC, or BPSC were observed in response to FE range of motion (ROM) or neutral zone (NZ). ROM was significantly higher in the UPS stage compared to BPS in response to LB and AT loading. ROM was significantly higher in UPSC compared to BPSC in response to LB loading only. Similarly, NZ was significantly higher in UPSC compared to BPSC in response to only LB loading. In response to AT loading, ROM was significantly higher during UPS than BPS or BPSC; however, no significant differences were noted between UPSC and BPSC with respect to AT ROM or NZ. Conclusion. BPS fixation is biomechanically superior to UPS fixation in multilevel PLIF constructs. This was most pronounced during both LB loading. Interbody support did contribute significantly to immediate stability.
引用
收藏
页数:8
相关论文
共 21 条
[1]   Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study [J].
Ambati, Divya V. ;
Wright, Edward K., Jr. ;
Lehman, Ronald A., Jr. ;
Kang, Daniel G. ;
Wagner, Scott C. ;
Dmitriev, Anton E. .
SPINE JOURNAL, 2015, 15 (08) :1812-1822
[2]   Bilateral Pedicle Screw Fixation versus Unilateral Pedicle and Contralateral Facet Screws for Minimally Invasive Transforaminal Lumbar Interbody Fusion: Clinical Outcomes and Cost Analysis [J].
Awad, Basem I. ;
Lubelski, Daniel ;
Shin, John H. ;
Carmody, Margaret A. ;
Hoh, Daniel J. ;
Mroz, Thomas E. ;
Steinmetz, Michael P. .
GLOBAL SPINE JOURNAL, 2013, 3 (04) :225-230
[3]   Range of Motion of the Intact Lumbar Segment: A Multivariate Study of 42 Lumbar Spines [J].
Cook, Daniel J. ;
Yeager, Matthew S. ;
Cheng, Boyle C. .
INTERNATIONAL JOURNAL OF SPINE SURGERY, 2015, 9
[4]   An analysis of fusion cage migration in unilateral and bilateral fixation with transforaminal lumbar interbody fusion [J].
Duncan, Jan William ;
Bailey, Richard Anthony .
EUROPEAN SPINE JOURNAL, 2013, 22 (02) :439-445
[5]   Biomechanical Stability Afforded by Unilateral Versus Bilateral Pedicle Screw Fixation with and without Interbody Support Using Lateral Lumbar Interbody Fusion [J].
Godzik, Jakub ;
Martinez-del-Campo, Eduardo ;
Newcomb, Anna G. U. S. ;
Reis, Marco T. ;
Perez-Orribo, Luis ;
Whiting, Alexander C. ;
Singh, Vaneet ;
Kelly, Brian P. ;
Crawford, Neil R. .
WORLD NEUROSURGERY, 2018, 113 :E439-E445
[6]   Test protocols for evaluation of spinal implants [J].
Goel, VK ;
Panjabi, MM ;
Patwardhan, AG ;
Dooris, AP ;
Serhan, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A :103-109
[7]   Biomechanical Analysis of Fusion Segment Rigidity Upon Stress at Both the Fusion and Adjacent Segments: A Comparison between Unilateral and Bilateral Pedicle Screw Fixation [J].
Kim, Ho-Joong ;
Kang, Kyoung-Tak ;
Chang, Bong-Soon ;
Lee, Choon-Ki ;
Kim, Jang-Woo ;
Yeom, Jin S. .
YONSEI MEDICAL JOURNAL, 2014, 55 (05) :1386-1394
[8]   Adjacent Segment Pathology after Lumbar Spinal Fusion [J].
Lee, Jae Chul ;
Choi, Sung-Woo .
ASIAN SPINE JOURNAL, 2015, 9 (05) :807-817
[9]   A biomechanical comparison of 3 different posterior fixation techniques for 2-level lumbar spinal disorders [J].
Liu, Fubing ;
Feng, Zhenzhou ;
Liu, Tianze ;
Fei, Qinming ;
Jiang, Chun ;
Li, Yuanchao ;
Jiang, Xiaoxing ;
Dong, Jian .
JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (03) :375-380
[10]   Unilateral versus bilateral pedicle screw fixation with posterior lumbar interbody fusion for lumbar degenerative diseases A meta-analysis [J].
Liu, Huan ;
Xu, Ying ;
Yang, Si-Dong ;
Wang, Tao ;
Wang, Hui ;
Liu, Feng-Yu ;
Ding, Wen-Yuan .
MEDICINE, 2017, 96 (21)