Microscopic imaging of slow flow and diffusion: A pulsed field gradient stimulated echo sequence combined with turbo spin echo imaging

被引:37
作者
Scheenen, TWJ [1 ]
Vergeldt, FJ [1 ]
Windt, CW [1 ]
de Jager, PA [1 ]
Van As, H [1 ]
机构
[1] Univ Wageningen & Res Ctr, Dept Agrotechnol & Food Sci, Biophys Lab, NL-6703 HA Wageningen, Netherlands
关键词
MRI; dynamic NMR microscopy; T-1; PFG; STE; TSE; RARE;
D O I
10.1006/jmre.2001.2362
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper we present a pulse sequence that combines a displacement-encoded stimulated echo with rapid sampling of k-space by means of turbo spin echo imaging, The stimulated echo enables the use of long observation times between the two pulsed field gradients that sample q-space completely. Propagators, constructed with long observation times, could discriminate slowly flowing protons from diffusing protons, as shown in a phantom in which a plug flow with linear velocity of 50 mum/s could clearly be distinguished from stationary water. As a biological application the apparent diffusion constant in longitudinal direction of a transverse image of a maize plant stem had been measured as a function of observation time. Increasing contrast in the apparent diffusion constant image with increasing observation times were caused by differences in plant tissue: although the plant stem did not take up any water, the vascular bundles, concentrated in the outer ring of the stem, could still be discerned because of their longer unrestricted diffusional pathways for water in the longitudinal direction compared to cells in the parenchymal tissue. In the xylem region of a tomato pedicel Rowing water could be distinguished from a large amount of stationary water. Linear flow velocities up to 0.67 mm/s were measured with an observation time of 180 ms. (C) 2001 Academic Press.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 50 条
  • [41] Field inhomogeneity correction for gradient echo myelin water fraction imaging
    Alonso-Ortiz, Eva
    Levesque, Ives R.
    Paquin, Raphael
    Pike, G. Bruce
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) : 49 - 57
  • [42] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [43] 3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence
    Seo, Jung Min
    Yoon, Young Cheol
    Kwon, Jong Won
    ACTA RADIOLOGICA, 2011, 52 (10) : 1119 - 1124
  • [44] A multi-inversion multi-echo spin and gradient echo echo planar imaging sequence with low image distortion for rapid quantitative parameter mapping and synthetic image contrasts
    Manhard, Mary Kate
    Stockmann, Jason
    Liao, Congyu
    Park, Daniel
    Han, Sohyun
    Fair, Merlin
    van den Boomen, Maaike
    Polimeni, Jon
    Bilgic, Berkin
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 866 - 880
  • [45] Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence
    Choi, Kyu Sung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In One
    ACTA RADIOLOGICA, 2020, 61 (10) : 1406 - 1413
  • [46] Intravoxel Incoherent Motion in Normal Pituitary Gland: Initial Study with Turbo Spin-Echo Diffusion-Weighted Imaging
    Kamimura, K.
    Nakajo, M.
    Fukukura, Y.
    Iwanaga, T.
    Saito, T.
    Sasaki, M.
    Fujisaki, T.
    Takemura, A.
    Okuaki, T.
    Yoshiura, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2328 - 2333
  • [47] Frequency-dependent diffusion kurtosis imaging in the human brain using an oscillating gradient spin echo sequence and a high-performance head-only gradient
    Dai, Erpeng
    Zhu, Ante
    Yang, Grant K.
    Quah, Kristin
    Tan, Ek T.
    Fiveland, Eric
    Foo, Thomas K. F.
    Mcnab, Jennifer A.
    NEUROIMAGE, 2023, 279
  • [48] Technical note: Accuracy and precision of T2 and T2 with a gradient-echo spin-echo (GESE) sequence for cardiac imaging
    Huang, Qi
    Mendes, Jason
    Adluru, Ganesh
    DiBella, Edward
    MEDICAL PHYSICS, 2023, 50 (12) : 7946 - 7954
  • [49] Reducing Distortions in Diffusion-Weighted Echo Planar Imaging With a Dual-Echo Blip-Reversed Sequence
    Gallichan, Daniel
    Andersson, Jesper L. R.
    Jenkinson, Mark
    Robson, Matthew D.
    Miller, Karla L.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 382 - 390
  • [50] Evaluation of the Canine Intervertebral Disc Structure in Turbo Spin Echo-T2 and Fast Field Echo-T1 Sequences in Magnetic Resonance Imaging
    Kunze, Katarina
    Stein, Veronika Maria
    Tipold, Andrea
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6