Microscopic imaging of slow flow and diffusion: A pulsed field gradient stimulated echo sequence combined with turbo spin echo imaging

被引:37
|
作者
Scheenen, TWJ [1 ]
Vergeldt, FJ [1 ]
Windt, CW [1 ]
de Jager, PA [1 ]
Van As, H [1 ]
机构
[1] Univ Wageningen & Res Ctr, Dept Agrotechnol & Food Sci, Biophys Lab, NL-6703 HA Wageningen, Netherlands
关键词
MRI; dynamic NMR microscopy; T-1; PFG; STE; TSE; RARE;
D O I
10.1006/jmre.2001.2362
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper we present a pulse sequence that combines a displacement-encoded stimulated echo with rapid sampling of k-space by means of turbo spin echo imaging, The stimulated echo enables the use of long observation times between the two pulsed field gradients that sample q-space completely. Propagators, constructed with long observation times, could discriminate slowly flowing protons from diffusing protons, as shown in a phantom in which a plug flow with linear velocity of 50 mum/s could clearly be distinguished from stationary water. As a biological application the apparent diffusion constant in longitudinal direction of a transverse image of a maize plant stem had been measured as a function of observation time. Increasing contrast in the apparent diffusion constant image with increasing observation times were caused by differences in plant tissue: although the plant stem did not take up any water, the vascular bundles, concentrated in the outer ring of the stem, could still be discerned because of their longer unrestricted diffusional pathways for water in the longitudinal direction compared to cells in the parenchymal tissue. In the xylem region of a tomato pedicel Rowing water could be distinguished from a large amount of stationary water. Linear flow velocities up to 0.67 mm/s were measured with an observation time of 180 ms. (C) 2001 Academic Press.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 50 条
  • [1] CINE Turbo Spin Echo Imaging
    Mendes, Jason
    Parker, Dennis L.
    Hulet, Jordan
    Treiman, Gerald S.
    Kim, Seong-Eun
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (05) : 1286 - 1292
  • [2] Spin Echo Versus Stimulated Echo Diffusion Tensor Imaging of the In Vivo Human Heart
    von Deuster, Constantin
    Stoeck, Christian T.
    Genet, Martin
    Atkinson, David
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 862 - 872
  • [3] RADIAL TURBO SPIN-ECHO IMAGING
    RASCHE, V
    HOLZ, D
    SCHEPPER, W
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 629 - 638
  • [4] Density weighted turbo spin echo imaging
    Zeller, Mario
    Gutberlet, Marcel
    Staeb, Daniel
    Ritter, Christian Oliver
    Beer, Meinrad
    Hahn, Dietbert
    Koestler, Herbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 965 - 973
  • [5] Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla
    Hilbert, Fabian
    Wech, Tobias
    Neubauer, Henning
    Veldhoen, Simon
    Bley, Thorsten Alexander
    Koestler, Herbert
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 193 - 201
  • [6] Experimental O-Space Turbo Spin Echo Imaging
    Wang, Haifeng
    Tam, Leo
    Kopanoglu, Emre
    Peters, Dana C.
    Constable, R. Todd
    Galiana, Gigi
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1654 - 1661
  • [7] Diffusion-weighted imaging of the brain at 7 T with echo-planar and turbo spin echo sequences: preliminary results
    Sigmund, Eric E.
    Gutman, David
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 752 - 765
  • [8] Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging
    Van, Anh T.
    Cervantes, Barbara
    Kooijman, Hendrik
    Karampinos, Dimitrios C.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2017, 7 (02) : 238 - 250
  • [9] ACQUISITION OF SPIN-ECHO AND STIMULATED ECHO BY A SINGLE SEQUENCE - APPLICATION TO MRI OF DIFFUSION
    FRANCONI, F
    SONIER, CB
    SEGUIN, F
    LEPAPE, A
    AKOKA, S
    MAGNETIC RESONANCE IMAGING, 1994, 12 (04) : 605 - 611
  • [10] Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging
    Wan, Qi
    Lei, Qiang
    Wang, Peng
    Hu, Jianfeng
    Zhang, Tianjing
    Yu, Deng
    Li, Xinchun
    Liang, Changhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 334 - 340