Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

被引:60
作者
Nutting, CM
Rowbottom, CG
Cosgrove, VP
Henk, JM
Dearnaley, DP
Robinson, MH
Conway, J
Webb, S
机构
[1] Inst Canc Res, Dept Radiotherapy, Sutton, Surrey, England
[2] Royal Marsden NHS Trust, Sutton, Surrey, England
[3] Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[4] Weston Pk Hosp, YCR Dept Clin Oncol, Sheffield, S Yorkshire, England
[5] Weston Pk Hosp, Dept Radiotherapy Phys, Sheffield, S Yorkshire, England
关键词
parotid gland tumours; conventional radiotherapy; conformal radiotherapy; intensity-modulated radiotherapy; optimisation; radiotherapy technique;
D O I
10.1016/S0167-8140(01)00339-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stern, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degrees from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 50 条
  • [41] Hypopharyngeal squamous cell carcinoma: Three-dimensional or Intensity-modulated radiotherapy? A single institution's experience
    KaLsoulakis, Evangelia
    Riaz, Nadeem
    Hu, Man
    Morris, Luc
    Sherman, Eric
    McBride, Sean
    Lee, Nancy
    LARYNGOSCOPE, 2016, 126 (03) : 620 - 626
  • [42] Comparison of dosimetric parameters and acute toxicity of intensity-modulated and three-dimensional radiotherapy in patients with cervix carcinoma: A randomized prospective study
    Naik, A.
    Gurjar, O. P.
    Gupta, K. L.
    Singh, K.
    Nag, P.
    Bhandari, V.
    CANCER RADIOTHERAPIE, 2016, 20 (05): : 370 - 376
  • [43] Application of a spacer gel to optimize three-dimensional conformal and intensity modulated radiotherapy for prostate cancer
    Pinkawa, Michael
    Corral, Nuria Escobar
    Caffaro, Mariana
    Piroth, Marc D.
    Holy, Richard
    Djukic, Victoria
    Otto, Gundula
    Schoth, Felix
    Eble, Michael J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 436 - 441
  • [44] Effect of intensity-modulated radiotherapy versus two-dimensional conventional radiotherapy alone in nasopharyngeal carcinoma
    OuYang, Pu-Yun
    Shi, Dingbo
    Sun, Rui
    Zhu, Yu-Jia
    Xiao, Yao
    Zhang, Lu-Ning
    Zhang, Xu-Hui
    Chen, Ze-Ying
    Lan, Xiao-Wen
    Tang, Jie
    Gao, Yuan-Hong
    Ma, Jun
    Deng, Wuguo
    Xie, Fang-Yun
    ONCOTARGET, 2016, 7 (22) : 33408 - 33417
  • [45] A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana
    Kyei, Kofi Adesi
    Daniels, Joseph
    Adom, Ameyaw Kwame
    Odonkor, Philip
    Nyantakyi, Andrew Yaw
    Adjabu, Dorothy Ekua
    ECANCERMEDICALSCIENCE, 2024, 18
  • [46] Three-dimensional conformal versus intensity-modulated radiotherapy dose planning in stereotactic radiotherapy: application of standard quality parameters for plan evaluation
    Grzadziel, Aleksandra
    Grosu, Anca-Ligia
    Kneschaurek, Peter
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04): : S87 - S94
  • [47] Comparison of Intensity Modulated Radiotherapy and Dynamic Three-Dimensional Conformal Radiotherapy With Regard to Dose Distribution and Sparing of Organs at Risk
    Hasegawa, Yuzo
    Iuchi, Toshihiko
    Osato, Katsunobu
    Kodama, Takashi
    Toyama, Naoki
    Hatano, Kazuo
    NEUROLOGIA MEDICO-CHIRURGICA, 2011, 51 (05) : 349 - 355
  • [48] A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    Karger, CP
    Jäkel, O
    Hartmann, GH
    Heeg, P
    MEDICAL PHYSICS, 1999, 26 (10) : 2125 - 2132
  • [49] Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using novalis system
    Ding, Meisong
    Newman, Francis
    Kavanagh, Brian D.
    Stuhr, Kelly
    Johnson, Tim K.
    Gaspar, Laurie E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04): : S82 - S86
  • [50] Comparison of the treatment outcomes of intensity-modulated radiotherapy and two-dimensional conventional radiotherapy in nasopharyngeal carcinoma patients with parapharyngeal space extension
    Tang, Ling-Long
    Chen, Lei
    Mao, Yan-Ping
    Li, Wen-Fei
    Sun, Ying
    Liu, Li-Zhi
    Lin, Ai-Hua
    Mai, Hai-Qiang
    Shao, Jian-Yong
    Li, Li
    Ma, Jun
    RADIOTHERAPY AND ONCOLOGY, 2015, 116 (02) : 167 - 173