Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

被引:60
|
作者
Nutting, CM
Rowbottom, CG
Cosgrove, VP
Henk, JM
Dearnaley, DP
Robinson, MH
Conway, J
Webb, S
机构
[1] Inst Canc Res, Dept Radiotherapy, Sutton, Surrey, England
[2] Royal Marsden NHS Trust, Sutton, Surrey, England
[3] Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[4] Weston Pk Hosp, YCR Dept Clin Oncol, Sheffield, S Yorkshire, England
[5] Weston Pk Hosp, Dept Radiotherapy Phys, Sheffield, S Yorkshire, England
关键词
parotid gland tumours; conventional radiotherapy; conformal radiotherapy; intensity-modulated radiotherapy; optimisation; radiotherapy technique;
D O I
10.1016/S0167-8140(01)00339-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stern, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degrees from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 50 条
  • [31] Comparison of Significant Carotid Stenosis for Nasopharyngeal Carcinoma between Intensity-Modulated Radiotherapy and Conventional Two-Dimensional Radiotherapy
    Wang Liao
    Haihong Zhou
    Shengnuo Fan
    Yuqiu Zheng
    Bei Zhang
    Zhongyan Zhao
    Songhua Xiao
    Shoumin Bai
    Jun Liu
    Scientific Reports, 8
  • [32] Comparison of the efficacy between intensity-modulated radiotherapy and two-dimensional conventional radiotherapy in stage II nasopharyngeal carcinoma
    Pan, Xin-Bin
    Chen, Kai-Hua
    Huang, Shi-Ting
    Jiang, Yan-Ming
    Ma, Jia-Lin
    Liang, Zhong-Guo
    Qu, Song
    Li, Ling
    Chen, Long
    Zhu, Xiao-Dong
    ONCOTARGET, 2017, 8 (44) : 78096 - 78104
  • [33] Quality of life and survival outcome for patients with nasopharyngeal carcinoma receiving three-dimensional conformal radiotherapy vs. intensity-modulated radiotherapy - A longitudinal study
    Fang, Fu-Min
    Chien, Chih-Yen
    Tsai, Wen-Ling
    Chen, Hui-Chun
    Hsu, Hsuan-Chih
    Lui, Chun-Chung
    Huang, Tai-Lin
    Huang, Hsuan-Ying
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (02): : 356 - 364
  • [34] Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?
    Hermanto, Ulrich
    Frija, Erik K.
    Lii, MingFwu J.
    Chang, Eric L.
    Mahajan, Anita
    Woo, Shiao Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1135 - 1144
  • [35] Dosimetric comparison of four different external beam partial breast irradiation techniques: Three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy
    Moon, Sung Ho
    Shin, Kyung Hwan
    Kim, Tae Hyun
    Yoon, Myonggeun
    Park, Soah
    Lee, Doo-Hyun
    Kim, Jong Won
    Kim, Dae Woong
    Park, Sung Yong
    Cho, Kwan Ho
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 66 - 73
  • [36] Intensity-modulated radiotherapy for stage I glottic cancer: a short-term outcomes compared with three-dimensional conformal radiotherapy
    Cho, Ick Joon
    Chung, Woong-Ki
    Lee, Joon Kyoo
    Lee, Min-Cheol
    Paek, Jayeong
    Kim, Yong-Hyub
    Jeong, Jae-Uk
    Yoon, Mee Sun
    Song, Ju-Young
    Nam, Taek-Keun
    Ahn, Sung-Ja
    Lee, Dong Hoon
    Yoon, Tae Mi
    Lim, Sang-Chul
    RADIATION ONCOLOGY JOURNAL, 2019, 37 (04): : 271 - 278
  • [37] A Comparison of Intensity-Modulated Radiotherapy With Simultaneous Integrated Boost With Three-Dimensional Conformal Radiotherapy With Sequential Boost for Locally Advanced Cervical Cancer: A Dosimetric Study
    Figueredo Negron, Carlos Ivan
    Gamboa Garay, Oscar
    Pabon Giron, Alexandra
    Esguerra Cantillo, Jose Alejandro
    Guerrero Lizcano, Eduardo
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [38] Results and prognostic factors of 3-dimensional conformal radiotherapy and intensity-modulated radiotherapy for esophageal carcinoma
    Tan, L.
    Xiao, Z.
    Zhang, H.
    Chen, D.
    Feng, Q.
    Zhou, Z.
    Lv, J.
    Liang, J.
    Hui, Z.
    Wang, L.
    Yin, W.
    NEOPLASMA, 2015, 62 (05) : 777 - 786
  • [39] Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
    Kinhikar, Rajesh Ashok
    Ghadi, Yogesh G.
    Sahoo, Priyadarshini
    Laskar, Sarbani Ghosh
    Deshpande, Deepak D.
    Shrivastava, Shyam K.
    Agarwal, Jaiprakash
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (04) : 190 - 197
  • [40] Analysis of rare periparotid recurrence after parotid gland -sparing intensity-modulated radiotherapy for nasopharyngeal carcinoma
    Xu, Y.
    Zhang, M.
    Yue, Q.
    Zong, J.
    Lin, J.
    Sun, R.
    Qiu, S.
    Lin, S.
    Pan, J.
    CANCER RADIOTHERAPIE, 2016, 20 (05): : 377 - 383